Tisch Scientific Polypropylene (PP) Syringe Filters, 1 µm, 20 mm, 100/Pk - SPEC18204
Tisch Scientific's sales team brings fast, courteous service to every filtration order, from first quote through fulfillment. Syringe filters span a wide range of membrane chemistries and pore sizes, so the format can be matched to the sample matrix and solvent system in use. Hydrophobic polypropylene suits solvent and non-aqueous sample streams and delivers nominal retention with high dirt-loading capacity. ABS construction carries high impact strength into a small device and stands up to routine aqueous sample matrices. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.
Membrane Characteristics
- Extractable levels remain very low across the depth matrix
- Anion leaching stays very low from the matrix
- Nominal depth matrix distributes particulate load progressively through the medium volume
- PP/PE depth medium tolerates progressive particle accumulation as dirt-holding capacity fills
- Flexible polypropylene fiber matrix adapts to modest pressure cycles without fracture
Housing Characteristics
- Opaque body shields light-sensitive samples during the pass
- Tough ABS housing withstands repeated handling at the bench
- Housing integrity maintained at warm sample temperatures up to 80°C
- Housing-to-membrane seal keeps the sample from bypassing the membrane
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Request blanket-order pricing and paperwork support for your routine filtration purchases.
Sterilization Guidance
The device arrives factory sterile and is intended for single-use sample preparation.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- NA
- Burst Pressure (psi)
- 116psi
- Connection Type
- Double Luer Lock
- Construction
- Acrylonitrile Butadiene Styrene (ABS)
- Diameter
- 20mm
- Dimensions (W x D x H)
- 23mmx25.2mm
- Material
- Polypropylene (PP)
- Maximum Operating Pressure
- 72.5psi
- Maximum Operating Temperature (°C)
- 80℃
- Pack Count
- 100
- Pore Size (µm)
- 1.0
- Sterility
- Sterile
- Weight
- 0.72
- Wettability
- Hydrophobic
- Acetonitrile Sample Prep - Handles neat and diluted acetonitrile mobile phases and extracts for pharmaceutical and environmental workflows.
- Hormone and Steroid Testing - Handles alcohol and acetonitrile steroid extraction matrices for HPLC-MS confirmation in pharmaceutical QC labs.
- Biopharma Prefiltration - Removes large particulates from fermentation and upstream bioprocess streams ahead of membrane filtration steps.
- Textile Dye Wastewater - Processes aqueous and alcohol-containing dye effluents for absorbance monitoring and color removal tracking.
- Polymer Solution Prep - Handles THF and alcohol polymer solutions with high loads for GPC and SEC column protection and sample clarification.
- Trace Metal Analysis Prep - Introduces minimal metal ion background into the filtrate, supporting sample prep ahead of ICP-OES or ICP-MS analysis.