Polytetrafluoroethylene (PTFE) Syringe Filters - SF04525LCMS
When you're preparing samples for LC-MS analysis, background interference from extractables can ruin your results. These 0.45µm hydrophilic PTFE filters minimize contamination with an ultra-low extractables profile that won't introduce background peaks in your mass spectra. The hydrophilic surface processes aqueous samples immediately without pre-wetting, and the 0.45µm pore size removes particles while preserving your dissolved analytes. With 100µL holdup volume and 4.08cm² filtration area, you can process up to 50ml samples while maximizing recovery of precious analytical specimens.
Key PTFE Membrane Characteristics
- 0.45µm pore size removes particles while maintaining ultra-low extractables profile for clean LC-MS analysis
- Hydrophilic surface modification eliminates pre-wetting requirements for immediate aqueous sample processing
- Ultra-low extractables design prevents background interference in trace analytical applications
- Broad chemical compatibility withstands aggressive mobile phases and extraction solvents
- Low protein binding maintains analyte concentrations during sample preparation
Key Construction Characteristics
- 100µL holdup volume maximizes recovery of valuable analytical samples
- 25mm diameter with 4.08cm² filtration area processes medium-volume samples up to 50ml efficiently
- Low-extractables polypropylene housing minimizes contamination sources for trace analytical applications
- Luer-Lok/Luer Slip dual connection accommodates all standard laboratory syringe configurations
You can autoclave these filters at 121°C for 30 minutes when your protocols require pre-sterilization before use. The ultra-low extractables profile means you won't see background peaks interfering with your target analytes in mass spectra. Process samples at typical laboratory temperatures, and the 87psi burst pressure handles standard analytical workflows. The 21.75psi bubble point confirms consistent 0.45µm pore structure for reproducible particle removal across your LC-MS sample preparation runs.
For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 21.75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- PP
- Diameter
- 25mm
- Filtration Area
- 4.08cm²
- Flow Rate
- 35ml
- Holdup Volume
- 100μL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- No
- Prefilter Material
- /
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 50ml
- Weight
- 0.08
- Wetability
- Hydrophilic
- LC-MS Sample Clarification - Removes particulates from analytical samples without introducing extractables interference in mass detection
- Pharmaceutical Impurity Analysis - Clarifies drug formulations for trace impurity detection requiring ultra-clean filtration protocols
- Metabolomics Sample Preparation - Processes biological samples for mass spectrometry, preventing contaminating background peak formation
- Environmental Trace Analysis - Clarifies water and soil extracts for pesticide detection at parts-per-billion sensitivity levels
- Proteomics Research - Filters protein digests and peptide solutions for LC-MS/MS analysis with minimal extractables interference
- Quality Control Testing - Prepares pharmaceutical samples for trace analysis and release testing with maximum analytical accuracy