Polytetrafluoroethylene (PTFE) Syringe Filters - SF17507
Analytical chemistry laboratories, pharmaceutical micro-testing facilities, and precision research organizations require ultra-compact clarification solutions for micro-volume samples where particulate removal is critical without sacrificing precious specimen recovery. Advanced laboratory capabilities demand membrane technology that delivers validated 0.45μm clarification performance while maintaining ultra-minimal dead volume through precision engineering. Engineered with 4mm ultra-compact architecture and hydrophilic PTFE membrane chemistry, this filtration system provides efficient particulate removal through 21.75psi bubble point integrity validation. Design optimization includes 1μL ultra-minimal holdup volume for maximum micro-sample recovery, polypropylene prefilter integration protecting membrane integrity, and controlled 1.5ml flow rate characteristics processing 1ml micro-volume samples with precision suitable for demanding analytical workflows requiring both clarification performance and sample conservation.
Key PTFE Membrane Characteristics
- Validated 0.45μm Clarification Performance - Removes interfering particles while maintaining dissolved analyte passage for accurate micro-volume measurements
- Hydrophilic Surface Treatment - Modified fluoropolymer eliminates pre-wetting requirements, enabling immediate processing of aqueous micro-samples
- Chemical Stability Platform - Maintains compatibility with diverse analytical solvents while providing documented incompatibility guidelines
- Low Protein Adsorption - Preserves concentration of proteins and biologics through minimal surface binding in micro-volume processing
- 21.75psi Bubble Point Validation - Ensures consistent pore structure and clarification performance across manufacturing batches
Key Construction Characteristics
- 1μL Ultra-Minimal Holdup Volume - Optimizes yield through precision dead space engineering, maximizing recovery of ultra-precious micro-specimens
- Ultra-Compact 4mm Design - 0.125cm² effective area provides precise clarification control for micro-volume samples requiring maximum recovery
- Integrated Polypropylene Prefilter - Protects primary membrane from particulate damage while maintaining controlled 1.5ml flow characteristics
- Universal Dual Luer System - Luer-Lok/Luer Slip compatibility accommodates all standard laboratory precision syringe configurations
Built for your most precious micro-volume clarification requirements, this hydrophilic PTFE system delivers structural integrity through 87psi operational ratings while maintaining validated particulate removal. Your laboratory achieves maximum sample recovery through 1μL ultra-minimal holdup design and efficient processing through controlled flow characteristics, while the robust prefilter construction ensures consistent clarification performance across demanding analytical workflows where every microliter represents irreplaceable research value and cannot be sacrificed to filtration losses.
For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 21.75psi
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- PP
- Diameter
- 4mm
- Filtration Area
- 0.125cm²
- Flow Rate
- 1.5ml
- Holdup Volume
- 1μL
- Incompatibility
- Bases, esters, ethers, ketones
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 200
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- PP
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 1ml
- Wetability
- Hydrophilic
- Analytical Micro-Standards Clarification - Processes ultra-low volume reference materials for instrumental analysis with maximum sample recovery
- Pharmaceutical Micro-Formulation Testing - Clarifies drug candidates and test compounds for analytical procedures without sample loss
- Clinical Diagnostic Micro-Samples - Filters precious patient specimens for optical and spectroscopic analysis, requiring maximum recovery
- Mass Spectrometry Sample Preparation - Clarifies micro-volume samples for LC-MS analysis, protecting instrumentation from particulates
- Research Enzyme Solution Processing - Filters ultra-low volume biochemical reagents and enzyme solutions for sensitive applications
- Quality Control Micro-Testing - Clarifies small-volume test solutions for pharmaceutical analysis requiring precision and sample conservation