PTFE Hydrophilic Syringe Filters, 0.22 um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of PTFE Hydrophilic Syringe Filters, 0.22 um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase PTFE Hydrophilic Syringe Filters, 0.22 um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    PTFE Hydrophilic Syringe Filters, 0.22 um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF18001

    $143.95
    In Stock
     

    Tisch Scientific PTFE Syringe Filters, 0.22 µm, 25 mm, 100/Pk - SF18001

    Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. A sterilizing-grade syringe filter delivers point-of-use sterile filtration in a single-use format, without the housing and gasket maintenance a reusable stainless steel filter holder requires. Treated PTFE wets directly with aqueous samples while keeping solvent resistance and resists attack from the harshest process chemistries. The polypropylene housing presses snugly against the membrane during the pass while preserving sample chemistry across the flow path and maintains a low-dead-volume internal flow path. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.

    Membrane Characteristics

    • Solvent tolerance includes full-strength tetrahydrofuran and chlorinated solvents such as dichloromethane
    • High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
    • Chemical resistance spans the full pH 1 to 14 range
    • Non-fibrous, fully synthetic structure sheds no fibers into filtrate
    • Inert composition offers no nutrient source for microbial growth

    Housing Characteristics

    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate
    • Resists stress cracking from aqueous salt and buffer solutions
    • Polypropylene housing withstands rated backpressure from dense sample matrices without deformation
    • The seal formed against the membrane blocks bypass at rated operating pressure

    A particulate-laden aqueous sample makes the rest of your preparation unpredictable. General-purpose aqueous filtration supports the sample types you handle every day from reagent and buffer preparation through routine sample clarification. Request available pack sizes and lead times across this filtration line's membrane options from the Tisch Scientific team.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    43.51psi
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    18ml
    Holdup Volume
    100μL
    Incompatibility
    Bases, esters, ethers, ketones
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    0.22
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    NonSterile
    Sterilization
    Autoclave 121°C for 30min/ Gamma 25kGy
    Volume Throughput (ml)
    50ml
    Weight
    0.52
    Wettability
    Hydrophilic
    • Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
    • Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
    • Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
    • Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
    • Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.