Chat with us, powered by LiveChat

Secure Checkout
PTFE Hydrophilic Syringe Filters, 0.45um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of PTFE Hydrophilic Syringe Filters, 0.45um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase PTFE Hydrophilic Syringe Filters, 0.45um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    PTFE Hydrophilic Syringe Filters, 0.45um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF18138

    $168.99
    Only 19 in stock. Order now!
     

    Tisch Scientific PTFE Syringe Filters, 0.45 µm, 30 mm, 100/Pk - SF18138

    Tisch Scientific makes the ordering process straightforward, turning around requests for pricing and product information fast. Syringe filters replace the separate holder and vacuum apparatus of bulk filtration with a single disposable unit, eliminating cleaning between samples. Hydrophilic PTFE accepts aqueous samples on contact without alcohol pre-wetting while withstanding aggressive organics that degrade other media and filters aggressive organic solvents without breakdown. The polypropylene housing presses snugly against the membrane during the pass while standing firm against aqueous acids, bases, and alcohols during regular handling and preserves sample chemistry across the flow path. For routine sample preparation across many methods, each analytical run starts with a consistent, particle-free sample without added hardware or a cleaning step.

    Membrane Characteristics

    • UL 94 V-0 rating confirms the highest self-extinguishing classification
    • Solvent tolerance includes full-strength tetrahydrofuran and chlorinated solvents such as dichloromethane
    • Hydrofluoric acid resistance holds even in fully acid-digested samples
    • Chemical resistance spans the full pH 1 to 14 range
    • Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C

    Housing Characteristics

    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate
    • Medical-grade polypropylene with broad chemical compatibility

    Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. Consistent aqueous clarification clears particulates without slowing your bench routine across the buffers and reagents your day-to-day prep depends on. Request details on payment terms or standing-order arrangements for your routine filtration purchases.

    Sterilization Guidance

    Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    21.75psi
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    30mm
    Filtration Area
    4.9cm²
    Flow Rate
    59ml
    Holdup Volume
    100μL
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    NonSterile
    Sterilization
    Autoclave 121°C for 30min/ Gamma 25kGy
    Volume Throughput (ml)
    110ml
    Weight
    0.91
    Wettability
    Hydrophilic
    • Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
    • Cryogenic Fluids - Delivers consistent performance across extreme temperature ranges, filtering cryogenic liquids with dependable, reliable results.
    • Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
    • Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
    • Toxicology Screening - Clarifies protein-precipitated serum, plasma, and urine extracts ahead of LC-MS or GC-MS drug screening analysis.