Chat with us, powered by LiveChat

Secure Checkout
PTFE Hydrophilic Syringe Filters, 0.45um, 4mm, Luer-Lok/Luer Slip, Sterile, 100 /Pk

Thumbnail Filmstrip of PTFE Hydrophilic Syringe Filters, 0.45um, 4mm, Luer-Lok/Luer Slip, Sterile, 100 /Pk Images

    Purchase PTFE Hydrophilic Syringe Filters, 0.45um, 4mm, Luer-Lok/Luer Slip, Sterile, 100 /Pk

    PTFE Hydrophilic Syringe Filters, 0.45um, 4mm, Luer-Lok/Luer Slip, Sterile, 100 /Pk
    Tisch SKU: SF18246

    $176.99
    Ships in 4 weeks
     

    Tisch Scientific PTFE Syringe Filters, 0.45 µm, 4 mm, 100/Pk - SF18246

    Tisch Scientific makes the ordering process straightforward, turning around requests for pricing and product information fast. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. The PTFE matrix handles concentrated acids and bases across demanding methods and resists attack from the harshest process chemistries. The polypropylene housing presses snugly against the membrane during the pass while arriving pre-sterilized and individually wrapped for aseptic sample preparation and routes flow to minimize backpressure in service. When chromatographic methods demand particle-free injections, the column stays clean from run to run, protecting method performance and column life.

    Membrane Characteristics

    • Biological inertness resists enzymatic attack from proteases and lipases
    • Absolute pore rating delivers reproducible retention across every protocol
    • Aqueous buffers and HPLC mobile phases wet the hydrophilic surface instantly
    • Inert composition offers no nutrient source for microbial growth
    • Chemical resistance spans the full pH 1 to 14 range

    Housing Characteristics

    • Sterile barrier packaging assures the housing's factory-sterilized state is intact at the point of use
    • Polypropylene housing retains its chemical integrity under vaporized hydrogen peroxide decontamination cycles used in aseptic processing isolators
    • The seal formed against the membrane blocks bypass at rated operating pressure
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics

    Juggling several filter types for one routine clarification eats up your bench time. General-purpose aqueous filtration supports the sample types you handle every day from reagent and buffer preparation through routine sample clarification. Standardize your filtration purchases across every method with volume pricing and documentation from the Tisch Scientific team.

    Sterilization Guidance

    Sterile single-use packaging removes any in-lab sterilization preparation step.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    21.75psi
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    4mm
    Filtration Area
    0.125cm²
    Flow Rate
    1.5ml
    Holdup Volume
    1μL
    Incompatibility
    Bases, esters, ethers, ketones
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Sterile
    Volume Throughput (ml)
    1ml
    Weight
    0.33
    Wettability
    Hydrophilic
    • Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
    • Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
    • Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
    • Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
    • Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
    • Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.