Your Cart (0)
Polytetrafluoroethylene (PTFE) Syringe Filters - GD17035
When you're filtering aggressive solvents and corrosive reagents, you need the broadest chemical resistance available. These 0.22µm PTFE filters with integrated GD-4 glass fiber prefilters handle everything from strong acids to challenging organics like DMF and chloroform. The hydrophobic membrane removes bacteria from non-aqueous solutions while the glass fiber layer captures large particles upstream, extending membrane life in high-particulate samples.
Key Polytetrafluoroethylene (PTFE) Membrane Characteristics
- Hydrophobic membrane requires pre-wetting with alcohol for aqueous solutions
- Universal chemical resistance withstands all organic solvents, acids, and bases
- Exceptional thermal stability maintains integrity at 60°C continuous operation
- Autoclavable construction enables sterilization at 121°C for 30 minutes when required
Key Construction Characteristics
- GD-4 glass fiber prefilter extends membrane life by capturing larger particulates upstream
- Dual Luer-Lok/Luer Slip connectivity accommodates all standard syringe configurations
- Polypropylene housing withstands 87psi burst pressure for secure high-pressure operations
- 100µl holdup volume minimizes sample loss when filtering valuable or limited reagents
For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 17.4psi
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- PP
- Diameter
- 25mm
- Filtration Area
- 4.08cm²
- Flow Rate
- 18ml
- Holdup Volume
- 100μL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 100ml
- Weight
- 0.70
- Wetability
- Hydrophobic
- Aggressive Solvent Filtration - Handles DMF, DMSO, THF, and chloroform where other membranes degrade, protecting analytical equipment downstream
- Sterile Filtration - Removes bacteria from non-aqueous pharmaceutical solutions and organic reagents requiring sterile-grade processing
- HPLC Sample Preparation - Protects chromatography columns from particulates in organic mobile phases while maintaining chemical compatibility
- Air and Gas Venting - Hydrophobic membrane permits gas passage while blocking aqueous contamination in laboratory equipment and vessels
- Strong Acid Handling - Filters concentrated HCl, H2SO4, and HNO3 without membrane degradation in chemical synthesis and analytical workflows
- Protein Precipitation Cleanup - Clarifies samples after TCA, acetonitrile, or methanol precipitation in proteomics sample preparation