    Tisch Scientific PTFE Syringe Filters, 0.45 µm, 25 mm, 100/Pk - GD17036

    Tisch Scientific's product lineup extends from filtration membranes to devices and the consumable supplies laboratories use daily. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. The hydrophobic PTFE membrane suits gas, vent, and solvent-stream filtration while handling concentrated acids and strong bases and reaches the same absolute retention on every run. The polypropylene housing holds its seal true run after run and stays inert across common laboratory solvents. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.

    Prefiltration

    • Glass microfiber prefilter shields the downstream membrane from bulk particulate
    • Upstream glass microfiber prefilter layer captures coarse particulate ahead of the membrane
    • Two-stage construction pairs a glass microfiber depth prefilter with the final membrane
    • Glass microfiber depth media loads particulate across its full thickness

    Membrane Characteristics

    • Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
    • Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
    • Low extractables keep the chromatographic background clean
    • Hydrofluoric acid resistance holds even in fully acid-digested samples
    • Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack

    Housing Characteristics

    • Translucent housing wall allows visual confirmation of sample flow during filtration
    • Rigid polypropylene body maintains its geometry through routine filtration pressure
    • Plasticizer-free polyolefin construction keeps the fluid path clean
    • Stable across the full aqueous pH range in routine sample work

    A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Request a quality certificate, lot documentation, or a blanket-order quote for your filtration order at any time.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    7.25(absolute ethyl alcohol )
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    35ml
    Holdup Volume
    100μL
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Sterility
    NonSterile
    Sterilization
    Autoclave 121°C for 30min/ Gamma 25kGy
    Volume Throughput (ml)
    100ml
    Weight
    0.70
    Wettability
    Hydrophobic
    • Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
    • Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
    • Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
    • Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
    • Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.
    • Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.