Tisch Scientific PTFE Syringe Filters, 0.22 µm, 13 mm, 100/Pk - SF14466
Tisch Scientific reduces per-unit costs for laboratories that place blanket purchase agreements or large-quantity orders. A syringe filter with a hydrophobic vent-rated membrane keeps gas and vent lines free of microbial ingress. The hydrophobic PTFE membrane suits gas, vent, and solvent-stream filtration while withstanding aggressive organics that degrade other media and delivers sterilizing-grade gas and vent filtration. Polypropylene construction maintains a low-dead-volume internal flow path and leaves no seam for sample to bypass the membrane. No separate sterilization cycle is needed when the gas path already runs through a validated sterile-grade membrane.
Membrane Characteristics
- High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
- Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
- Ionic and metallic extractable levels stay very low
- Hydrofluoric acid resistance holds even in fully acid-digested samples
- Chemical resistance spans the full pH 1 to 14 range
Housing Characteristics
- Optimized internal geometry minimizes backpressure in service
- Medical-grade polypropylene with broad chemical compatibility
- The seal formed against the membrane blocks bypass at rated operating pressure
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Reliable solvent prefiltration keeps a stray particulate from carrying into your downstream work from reaction mixtures and crude extracts through further processing. Request blanket-order pricing and paperwork support for your routine filtration purchases.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 17.4(absolute ethyl alcohol )
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 13mm
- Filtration Area
- 1.09cm²
- Flow Rate
- 5.5ml
- Holdup Volume
- 10μL
- Incompatibility
- Aqueous samples without rewetting
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 10ml
- Weight
- 0.19
- Wettability
- Hydrophobic
- Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
- Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
- Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.