Chat with us, powered by LiveChat

Secure Checkout
PTFE Syringe Filter, 0.45 m, 25 mm, Luer-Lok/Luer Slip, Non-Sterile, 100/Pk

Thumbnail Filmstrip of PTFE Syringe Filter, 0.45 m, 25 mm, Luer-Lok/Luer Slip, Non-Sterile, 100/Pk Images

    Purchase PTFE Syringe Filter, 0.45 m, 25 mm, Luer-Lok/Luer Slip, Non-Sterile, 100/Pk

    PTFE Syringe Filter, 0.45 m, 25 mm, Luer-Lok/Luer Slip, Non-Sterile, 100/Pk
    Tisch SKU: SF14469

    $115.99
    In Stock
     

    Tisch Scientific PTFE Syringe Filters, 0.45 µm, 25 mm, 100/Pk - SF14469

    Tisch Scientific reduces per-unit costs for laboratories that place blanket purchase agreements or large-quantity orders. Syringe filters replace the separate holder and vacuum apparatus of bulk filtration with a single disposable unit, eliminating cleaning between samples. PTFE stays chemically inert against aggressive solvents, strong acids, and alkalis in service while handling concentrated acids and strong bases and suits gas, vent, and solvent-stream filtration. The polypropylene housing resists aqueous acids, bases, and alcohols in routine use while holding its seal true run after run and preserves sample chemistry across the flow path. When chromatographic methods demand particle-free injections, the column stays clean from run to run, protecting method performance and column life.

    Membrane Characteristics

    • Surface energy near 18.5 dynes per centimeter repels oils and nonpolar liquids
    • Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
    • Minimal moisture absorption pairs with a low tare mass
    • Insolubility in all known organic solvents avoids swelling and pore distortion
    • Hydrofluoric acid resistance holds even in fully acid-digested samples

    Housing Characteristics

    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Translucent housing wall allows visual confirmation of sample flow during filtration
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate

    A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Request available pack sizes and lead times across this filtration line's membrane options from the Tisch Scientific team.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    7.25(absolute ethyl alcohol )
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    35ml
    Holdup Volume
    100μL
    Incompatibility
    Aqueous samples without rewetting
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Sterility
    NonSterile
    Sterilization
    Autoclave 121°C for 30min/ Gamma 25kGy
    Volume Throughput (ml)
    100ml
    Weight
    0.52
    Wettability
    Hydrophobic
    • Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
    • Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
    • Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
    • Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
    • Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
    • Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.