Tisch Scientific PTFE Syringe Filters, 0.45 µm, 13 mm, 100/Pk - SF14473
Tisch Scientific's product lineup extends from filtration membranes to devices and the consumable supplies laboratories use daily. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. Hydrophobic PTFE repels water while passing gases and solvents freely while resisting attack from the harshest process chemistries and filters aggressive organic solvents without breakdown. Polyolefin construction sheds virtually no extractable material into the sample and presses snugly against the membrane during the pass. When chromatographic methods demand particle-free injections, the column stays clean from run to run, protecting method performance and column life.
Membrane Characteristics
- Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
- Gas-venting and liquid-blocking function survives repeated autoclave sterilization cycles
- Low extractables keep the chromatographic background clean
- Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
- High porosity minimizes hold-up volume for small sample volumes
Housing Characteristics
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Sterile barrier packaging assures the housing's factory-sterilized state is intact at the point of use
- Polypropylene housing tolerates ethylene oxide gas sterilization cycles without softening or dimensional distortion
- Standardized luer connection geometry provides secure engagement with standard syringe tips
An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.
Sterilization Guidance
Sterile single-use packaging removes any in-lab sterilization preparation step.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 7.25(absolute ethyl alcohol )
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 13mm
- Filtration Area
- 1.09cm²
- Flow Rate
- 11ml
- Holdup Volume
- 10μL
- Incompatibility
- Aqueous samples without rewetting
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.45
- Sterility
- Sterile
- Volume Throughput (ml)
- 10ml
- Weight
- 0.40
- Wettability
- Hydrophobic
- Toxicology Screening - Clarifies protein-precipitated serum, plasma, and urine extracts ahead of LC-MS or GC-MS drug screening analysis.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.