    Tisch Scientific PTFE Syringe Filters, 1 µm, 25 mm, 100/Pk - SF15172

    Tisch Scientific reduces per-unit costs for laboratories that place blanket purchase agreements or large-quantity orders. Syringe filters replace the separate holder and vacuum apparatus of bulk filtration with a single disposable unit, eliminating cleaning between samples. PTFE suits solvent and reagent filtration where other membranes fail and excludes particles larger than the declared micron limit. Thermal-bonded PP construction leaves no seam for sample to bypass the membrane while maintaining a low-dead-volume internal flow path and delivers a chemically clean filtrate to the downstream step. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.

    Membrane Characteristics

    • High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
    • Non-wetting pore surface blocks liquid water while passing water vapor freely
    • Hydrofluoric acid resistance holds even in fully acid-digested samples
    • Node-fibril microstructure resists compaction under sustained operating pressure
    • High porosity minimizes hold-up volume for small sample volumes

    Housing Characteristics

    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
    • Plasticizer-free polyolefin construction keeps the fluid path clean
    • Rigid polypropylene body maintains its geometry through routine filtration pressure
    • Rated operating pressure supports filtration of high-resistance and viscous samples without housing distortion

    A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Request available pack sizes and lead times across this filtration line's membrane options from the Tisch Scientific team.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    4.35(absolute ethyl alcohol )
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    70ml
    Holdup Volume
    100μL
    Incompatibility
    Aqueous samples without rewetting
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    1.0
    Sterility
    NonSterile
    Sterilization
    Autoclave 121°C for 30min/ Gamma 25kGy
    Volume Throughput (ml)
    100ml
    Weight
    0.52
    Wettability
    Hydrophobic
    • Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
    • Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
    • Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
    • Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
    • Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
    • Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.