PTFE Syringe Filters, 0.45um, 17mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of PTFE Syringe Filters, 0.45um, 17mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase PTFE Syringe Filters, 0.45um, 17mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    PTFE Syringe Filters, 0.45um, 17mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF15623

    $120.99
    In Stock
     

    Tisch Scientific PTFE Syringe Filters, 0.45 µm, 17 mm, 100/Pk - SF15623

    Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. PTFE delivers absolute particle cutoff at the rated pore size while repelling water and passing gases and solvents freely and resists attack from the harshest process chemistries. The PP housing stays inert across common laboratory solvents and buffers in routine use while keeping sample purity intact through the filtration pass and routes flow to minimize backpressure in service. For routine sample preparation across many methods, each analytical run starts with a consistent, particle-free sample without added hardware or a cleaning step.

    Membrane Characteristics

    • Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
    • Low extractables keep the chromatographic background clean
    • Biological inertness resists enzymatic attack from proteases and lipases
    • Ionic and metallic extractable levels stay very low
    • Non-wetting pore surface blocks liquid water while passing water vapor freely

    Housing Characteristics

    • Translucent housing wall allows visual confirmation of sample flow during filtration
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Standardized luer connection geometry provides secure engagement with standard syringe tips

    Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Reliable solvent prefiltration keeps a stray particulate from carrying into your downstream work so your downstream method starts with a clean sample. Request comparable filtration options that may offer cost savings for your order from the Tisch Scientific team.

    Sterilization Guidance

    Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    7.25(absolute ethyl alcohol )
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    17mm
    Filtration Area
    1.65cm²
    Flow Rate
    20ml
    Holdup Volume
    20μL
    Incompatibility
    Aqueous samples without rewetting
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Sterility
    NonSterile
    Sterilization
    Autoclave 121°C for 30min/ Gamma 25kGy
    Volume Throughput (ml)
    20ml
    Weight
    0.33
    Wettability
    Hydrophobic
    • Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
    • Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
    • Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
    • Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
    • Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.