Tisch Scientific PTFE Syringe Filters, 0.45 µm, 30 mm, 100/Pk - SF16000
Tisch Scientific's sales team brings fast, courteous service to every filtration order, from first quote through fulfillment. Many syringe filters ship with lot-specific quality documentation, giving analysts documented traceability beyond what an ad hoc bulk filtration setup typically provides. The PTFE membrane clarifies solvent streams at the rated pore size while filtering aggressive organic solvents without breakdown and withstands aggressive organics that degrade other media. Polypropylene construction maintains a low-dead-volume internal flow path and presses snugly against the membrane during the pass. Where analytical results depend on clean samples, the preparation step stays consistent from sample to sample through a pre-tested syringe filter.
Membrane Characteristics
- Gas-venting and liquid-blocking function survives repeated autoclave sterilization cycles
- Water contact angle near 120 degrees marks strong hydrophobicity
- Inert composition offers no nutrient source for microbial growth
- UL 94 V-0 rating confirms the highest self-extinguishing classification
- Chemical resistance spans the full pH 1 to 14 range
Housing Characteristics
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
- Rated operating pressure supports filtration of high-resistance and viscous samples without housing distortion
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Request comparable filtration options that may offer cost savings for your order from the Tisch Scientific team.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 7.25(absolute ethyl alcohol )
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 30mm
- Filtration Area
- 4.9cm²
- Flow Rate
- 59ml
- Holdup Volume
- 100μL
- Incompatibility
- Aqueous samples without rewetting
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.45
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 120ml
- Weight
- 0.91
- Wettability
- Hydrophobic
- Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
- Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.