Tisch Scientific PTFE Syringe Filters, 3 µm, 33 mm, 100/Pk - SF17044
Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. A syringe filter dispenses filtrate directly into an autosampler vial, without the intermediate collection vessel a bulk vacuum filtration setup typically needs. PTFE stays chemically inert against aggressive solvents, strong acids, and alkalis in service while handling concentrated acids and strong bases and suits gas, vent, and solvent-stream filtration. Polypropylene construction resists chemical degradation from routine sample matrices and sustains efficient flow on viscous samples. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.
Membrane Characteristics
- Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
- UL 94 V-0 rating confirms the highest self-extinguishing classification
- Inert composition offers no nutrient source for microbial growth
- Minimal moisture absorption pairs with a low tare mass
- Non-fibrous, fully synthetic structure sheds no fibers into filtrate
Housing Characteristics
- Rigid polypropylene body maintains its geometry through routine filtration pressure
- Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure
- The seal formed against the membrane blocks bypass at rated operating pressure
- Standardized luer connection geometry provides secure engagement with standard syringe tips
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Request a quality certificate, lot documentation, or a blanket-order quote for your filtration order at any time.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 2.9psi
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 33mm
- Filtration Area
- 4.6cm²
- Flow Rate
- 200ml
- Holdup Volume
- 100μL
- Incompatibility
- Aqueous samples without rewetting
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 3.0
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 120ml
- Weight
- 0.96
- Wettability
- Hydrophobic
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
- Toxicology Screening - Clarifies protein-precipitated serum, plasma, and urine extracts ahead of LC-MS or GC-MS drug screening analysis.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.