    Polytetrafluoroethylene (PTFE) Syringe Filters - SF17400

    Featuring hydrophobic PTFE membrane technology optimized for coarse prefiltration of aggressive organic solvents and particulate-laden samples. A 5.0µm pore configuration delivers ultra-high flow rates while maintaining complete chemical inertness to concentrated acids, bases, and challenging reagents. Tisch Scientific combines ultra-resistant PTFE membranes with optimized 25mm construction to provide rapid prefiltration and clarification of heavily contaminated chemical samples.

    Key Polytetrafluoroethylene (PTFE) Membrane Characteristics

    • Hydrophobic membrane requires alcohol pre-wetting for aqueous solution compatibility
    • Universal chemical resistance handles all organic solvents, acids, and bases without degradation
    • Exceptional thermal stability maintains performance at a 60°C continuous operating temperature
    • 5.0µm pore size provides coarse prefiltration and removal of large particulates
    • Autoclavable construction enables sterilization at 121°C for validated protocols

    Key Construction Characteristics

    • Polypropylene housing delivers chemical resistance while withstanding 87psi burst pressure
    • Dual Luer-Lok/Luer Slip compatibility accommodates all standard syringe configurations
    • Standard 25mm diameter balances exceptional flow rate with practical handling characteristics
    • 100µl holdup volume minimizes loss when filtering valuable reagents and limited samples

    SF17400 syringe filters achieve exceptional 240ml/min flow rates through a 4.08cm² active membrane area, dramatically accelerating your prefiltration workflows even with heavily particulated samples. Outstanding flow characteristics minimize processing time while the 100ml throughput capacity handles your challenging samples requiring rapid clarification. Autoclave compatibility at 121°C transforms nonsterile units into validated sterile filters, providing flexibility for your applications demanding both absolute chemical resistance and coarse particle removal.

    For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    1.45(absolute ethyl alcohol )
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    PP
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    240ml
    Holdup Volume
    100μL
    Incompatibility
    Aqueous samples without rewetting
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    5
    Sterility
    NonSterile
    Sterilization
    Autoclave 121°C for 30min/ Gamma 25kGy
    Volume Throughput (ml)
    100ml
    Wetability
    Hydrophobic
    • Coarse prefiltration - Removal of large particulates, precipitates, and suspended solids from reaction mixtures and crude extracts
    • Sample clarification - Initial filtration of heavily contaminated samples before fine filtration, protecting downstream 0.22 or 0.45µm filters
    • Aggressive solvents - High-flow prefiltration of THF, DMF, DMSO, chloroform, and acetonitrile containing visible particulates
    • Crystal removal - Rapid separation of crystallized products from mother liquors in organic synthesis and recrystallization procedures
    • Catalyst recovery - Removal of heterogeneous catalysts, activated carbon, and solid-phase reagents from organic reaction mixtures
    • Environmental samples - Prefiltration of soil extracts, sediment samples, and industrial waste streams before analytical testing