Tisch Scientific PTFE Syringe Filters, 0.22 µm, 4 mm, 200/Pk - SF17504
Tisch Scientific holds its filtration pricing at levels that let budget-conscious laboratories stretch procurement dollars further. Gas and vent service calls for a hydrophobic syringe filter rated to the same sterilizing-grade pore size as its liquid counterpart. Chemically inert PTFE achieves sterile-grade retention in gas and vent service while resisting attack from the harshest process chemistries and blocks aqueous ingress in vent applications. Thermal-bonded PP construction leaves no seam for sample to bypass the membrane while standing firm against aqueous acids, bases, and alcohols during regular handling and routes flow to minimize backpressure in service. No separate sterilization cycle is needed when the gas path already runs through a validated sterile-grade membrane.
Membrane Characteristics
- Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
- Insolubility in all known organic solvents avoids swelling and pore distortion
- Ionic and metallic extractable levels stay very low
- Validated against an aerosol Brevundimonas diminuta bacterial challenge
- Gas-venting and liquid-blocking function survives repeated autoclave sterilization cycles
Housing Characteristics
- Stable across the full aqueous pH range in routine sample work
- Polypropylene housing withstands rated backpressure from dense sample matrices without deformation
- Withstands standard 121°C steam autoclave cycles without softening or structural distortion
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 17.4psi
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 4mm
- Filtration Area
- 0.125cm²
- Flow Rate
- 0.7ml
- Holdup Volume
- 1μL
- Incompatibility
- Aqueous samples without rewetting
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 200
- Pore Size (µm)
- 0.22
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 1ml
- Weight
- 0.24
- Wettability
- Hydrophobic
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
- Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.