PTFE Syringe Filters, 0.45um, 4mm, Luer-Lok/Luer Slip, Nonsterile, 200/Pk

Thumbnail Filmstrip of PTFE Syringe Filters, 0.45um, 4mm, Luer-Lok/Luer Slip, Nonsterile, 200/Pk Images

    Purchase PTFE Syringe Filters, 0.45um, 4mm, Luer-Lok/Luer Slip, Nonsterile, 200/Pk

    PTFE Syringe Filters, 0.45um, 4mm, Luer-Lok/Luer Slip, Nonsterile, 200/Pk
    Tisch SKU: SF17505

    $193.99
    Only 6 in stock. Order now!
     

    Tisch Scientific PTFE Syringe Filters, 0.45 µm, 4 mm, 200/Pk - SF17505

    Tisch Scientific's product lineup extends from filtration membranes to devices and the consumable supplies laboratories use daily. A syringe filter's small hold-up volume limits sample loss, a meaningful difference when working with a limited or precious sample. Hydrophobic PTFE blocks aqueous ingress in vent and gas applications while resisting attack from the harshest process chemistries and handles concentrated acids and bases. The polypropylene housing holds its seal true run after run while shedding virtually no extractable material into the sample and routes flow to minimize backpressure in service. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.

    Membrane Characteristics

    • Chemical resistance spans the full pH 1 to 14 range
    • Non-fibrous, fully synthetic structure sheds no fibers into filtrate
    • Minimal moisture absorption pairs with a low tare mass
    • Biological inertness resists enzymatic attack from proteases and lipases
    • Non-wetting pore surface blocks liquid water while passing water vapor freely

    Housing Characteristics

    • Thermal-bonded construction keeps adhesives out of the fluid path
    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Optimized internal geometry minimizes backpressure in service
    • Translucent housing wall allows visual confirmation of sample flow during filtration

    Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Reliable solvent prefiltration keeps a stray particulate from carrying into your downstream work from reaction mixtures and crude extracts through further processing. Request a quality certificate, lot documentation, or a blanket-order quote for your filtration order at any time.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    7.25psi.
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    4mm
    Filtration Area
    0.125cm²
    Flow Rate
    1.5ml
    Holdup Volume
    1μL
    Incompatibility
    Aqueous samples without rewetting
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    200
    Pore Size (µm)
    0.45
    Sterility
    NonSterile
    Sterilization
    Autoclave 121°C for 30min/ Gamma 25kGy
    Volume Throughput (ml)
    1ml
    Weight
    0.24
    Wettability
    Hydrophobic
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
    • Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
    • Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
    • Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
    • Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
    • Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.