Tisch Scientific PTFE Syringe Filters, 0.22 µm, 4 mm, 100/Pk - SF18243
Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. A syringe filter with a hydrophobic vent-rated membrane keeps gas and vent lines free of microbial ingress. Chemically inert PTFE achieves sterile-grade retention in gas and vent service while resisting attack from the harshest process chemistries and filters aggressive organic solvents without breakdown. Pre-sterilized polypropylene construction is individually wrapped for direct use in sterile workflows while keeping sample purity intact through the filtration pass and sustains efficient flow on viscous samples. A vent or gas line stays free of airborne bacteria once a hydrophobic, sterilizing-grade membrane is in the path.
Membrane Characteristics
- Solvent tolerance includes full-strength tetrahydrofuran and chlorinated solvents such as dichloromethane
- Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
- Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
- Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
- Hydrofluoric acid resistance holds even in fully acid-digested samples
Housing Characteristics
- Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
- Thermal-bonded construction keeps adhesives out of the fluid path
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Standardized luer connection geometry provides secure engagement with standard syringe tips
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Start a live chat with the Tisch Scientific team for real-time updates on product availability, lead time, or your order status.
Sterilization Guidance
Sterile single-use packaging removes any in-lab sterilization preparation step.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 17.4(absolute ethyl alcohol )
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 4mm
- Filtration Area
- 0.125cm²
- Flow Rate
- 0.7ml
- Holdup Volume
- 1μL
- Incompatibility
- Aqueous samples without rewetting
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Sterility
- Sterile
- Volume Throughput (ml)
- 1ml
- Weight
- 0.33
- Wettability
- Hydrophobic
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
- Cryogenic Fluids - Delivers consistent performance across extreme temperature ranges, filtering cryogenic liquids with dependable, reliable results.
- Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.