Chat with us, powered by LiveChat
Secure Checkout
Hydrophilic PVDF Syringe Filters, 0.22 um, 33mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of Hydrophilic PVDF Syringe Filters, 0.22 um, 33mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase Hydrophilic PVDF Syringe Filters, 0.22 um, 33mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    Tisch
    Hydrophilic PVDF Syringe Filters, 0.22 um, 33mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk SKU: SF17391

    $187.95
    5 in stock. Additional units ship in 4 weeks.
     

    Polyvinylidene Fluoride (PVDF) Syringe Filters - SF17391

    Precision 0.22 µm hydrophilic polyvinylidene fluoride membrane technology features an integrated glass fiber prefilter. It delivers sterile-grade filtration for high-volume aqueous biological samples. The design supports bacterial retention and rapid flow characteristics. Pharmaceutical manufacturing workflows benefit from low protein binding. The configuration combines naturally wettable surface chemistry with a 4.6 cm² filtration area. Users can eliminate pre-treatment steps. Efficient sterilization of volumes exceeding 100 ml supports high-throughput biotechnology workflows. A dual-layer construction with 100 µL holdup volume preserves samples. The housing maintains compatibility with aqueous buffers and biological solutions demanding microbial control.

    Key Hydrophilic PVDF Membrane Characteristics

    • Naturally wettable hydrophilic surface eliminates alcohol pre-wetting requirements, enabling immediate processing of aqueous biological samples without preparatory solvent steps
    • 0.22 µm pore size provides sterile-grade filtration with validated bacterial retention, including Brevundimonas diminuta, ensuring microbial control
    • Low protein binding characteristics maintain the concentration of therapeutic proteins and biomolecules during sterilization, minimizing product loss
    • Broad chemical compatibility resists degradation from mild acids, bases, and biological buffers while maintaining stable operation across pharmaceutical formulation workflows
    • Rapid flow characteristics with a 24.5 ml/min flow rate reduce processing time for high-volume sterile filtration in cell culture and buffer preparation applications

    Key Construction Characteristics

    • 100 µL holdup volume optimizes yield by minimizing sample retention within the filter housing, preserving valuable biological materials
    • Polypropylene housing construction provides reliable performance to 87 psi maximum operating pressure with thermal stability to 60°C for diverse laboratory conditions
    • Dual Luer-Lok and Luer-Slip connections integrate seamlessly with standard laboratory syringes without adapters, streamlining aseptic transfer procedures
    • Glass fiber prefilter captures coarse particulates and cellular debris upstream of the sterilizing membrane, extending filter lifetime in high-particulate biological samples

    Biopharmaceutical laboratories processing high-volume aqueous samples require specific sterilization technology. It must combine bacterial retention with rapid throughput. Hydrophilic PVDF membranes deliver minimal protein loss alongside high-flow performance. Hydrophilic PVDF syringe filters deliver 0.22 µm sterile-grade performance. Naturally wettable membrane chemistry simplifies workflows. Integrated prefilter protection extends filter life. Built to support critical sterilization workflows, the solution provides reliability. Proven microbial retention and low protein binding support manufacturing applications.

    For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    43.51psi
    Connection Type
    Luer-Lok/ Luer Slip
    Diameter
    33mm
    Filtration Area
    4.6cm²
    Flow Rate
    24.5ml
    Holdup Volume
    100μL
    Material
    Polyvinylidene Fluoride (PVDF)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-130μm
    Pack Count
    100
    Pore Size (µm)
    0.22
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    GF
    Sterility
    Nonsterile
    Sterilization
    Autoclave at 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    110ml
    Weight
    0.96
    Wetability
    Hydrophilic
    • Cell Culture Media Sterilization - Removes bacteria from culture media and supplements for mammalian cell bioprocessing and research applications
    • Biological Buffer Preparation - Sterilizes phosphate buffers and saline solutions for pharmaceutical manufacturing and laboratory research
    • Vaccine and Biologic Sterilization - Filters pharmaceutical formulations and parenteral solutions for small-batch production applications
    • Protein Solution Processing - Sterilizes enzyme solutions and protein formulations while maintaining biological activity and concentration
    • Water Quality Testing - Provides sterile aqueous samples for microbiological analysis and environmental monitoring in regulatory compliance programs
    • Tissue Culture Supplement Filtration - Sterilizes growth factors and serum additives for cell culture, requiring contamination-free processing