Tisch Scientific holds its filtration pricing at levels that let budget-conscious laboratories stretch procurement dollars further. Sterilizing-grade syringe filters deliver sterile-grade retention as a single-use format, eliminating the autoclaving and cleaning cycle a reusable sterile filtration setup would require. PVDF resists HPLC mobile phases, alcohols, and mild hydrocarbons while suiting HPLC sample preparation with immediate, reliable uptake and blocks bacterial passage through its smallest rated openings. The polypropylene housing presses snugly against the membrane during the pass while maintaining a low-dead-volume internal flow path and stays inert across common laboratory solvents. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Membrane Characteristics
- Intrinsic protein binding runs lower than nylon or mixed cellulose ester
- Adsorptive loss of HPLC analytes stays immeasurably low
- Fluorinated polymer chemistry resists ozone, UV, and ionizing radiation
- Absolute pore rating ensures reproducible results between test runs
- Organic solvent resistance beats PES or nylon at comparable pore size
Housing Characteristics
- Rigid polypropylene body maintains its geometry through routine filtration pressure
- Standardized luer connection geometry provides secure engagement with standard syringe tips
- Sterile barrier packaging assures the housing's factory-sterilized state is intact at the point of use
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
Particulates in your buffers and mobile phases shorten column life and unsettle your baselines. Reliable particulate removal protects your instruments and your data across reagent, buffer, and mobile-phase preparation. Request available pack sizes and lead times across this filtration line's membrane options from the Tisch Scientific team.
Sterilization Guidance
The device arrives factory sterile and is intended for single-use sample preparation.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 43.51psi
- Connection Type
- Luer-Lok/Luer Slip
- Diameter
- 33mm
- Filtration Area
- 4.9cm²
- Flow Rate
- 24.5ml
- Holdup Volume
- 100μL
- Material
- Polyvinylidene Fluoride (PVDF)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 100-130μm
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- PP
- Sterility
- Sterile
- Volume Throughput (ml)
- 110ml
- Weight
- 1.46
- Wettability
- Hydrophilic
- Spectroscopy Prep - Provides optical clarity and low background interference, ideal for UV-Vis and fluorescence sample preparation work.
- Pre-Blot Sample Prep - Ensures ultra-low protein binding for maximum sample recovery ahead of sensitive immunodetection protocols and assays.
- IC Guard Filtration - Removes particulates from aqueous samples before ion analysis, keeping detector cells free of fouling between injections.
- Biological Samples - Clarifies protein-rich solutions without loss of target molecules, preserving sample integrity for critical downstream assays.
- Dissolution Testing - Removes undissolved particles from timed USP 711 dissolution aliquots, preventing skewed potency and release results.
- Beverage QC - Clarifies wine, beer, and juice samples ahead of HPLC testing for organic acids, sugars, and preservatives.