Tisch Scientific PVDF Syringe Filters, 0.22 µm, 13 mm, 100/Pk - SF14454
Tisch Scientific's sales team brings fast, courteous service to every filtration order, from first quote through fulfillment. Gas and vent service calls for a hydrophobic syringe filter rated to the same sterilizing-grade pore size as its liquid counterpart. PVDF provides sterilizing-grade retention at the rated sub-micron pore size while repelling water for dependable gas and vent filtration and resists HPLC mobile phases, alcohols, and mild hydrocarbons. The polypropylene housing preserves sample chemistry across the flow path while staying inert across common laboratory solvents and routes flow to minimize backpressure in service. Downstream equipment and work areas stay protected from airborne bacterial contamination once the vent path runs through the membrane.
Membrane Characteristics
- Autoclave sterilization cycles leave pore structure and flow performance intact
- Low ionic extractables preserve baseline stability in conductivity-based ion chromatography detection
- Hydrochloric, dilute nitric, and up to 90% sulfuric acid cause no attack
- Mechanically durable membrane holds integrity under filtration pressure
- Fluorinated polymer chemistry resists ozone, UV, and ionizing radiation
Housing Characteristics
- Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
- Minimal extractable release from the housing supports sensitive analytical work downstream
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Request available pack sizes and lead times across this filtration line's membrane options from the Tisch Scientific team.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 14.5psi
- Connection Type
- Luer-Lok/Luer Slip
- Diameter
- 13mm
- Filtration Area
- 1.09cm²
- Flow Rate
- 5ml
- Holdup Volume
- 10μL
- Material
- Polyvinylidene Fluoride (PVDF)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 100-130μm
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- PP
- Sterility
- Nonsterile
- Sterilization
- Autoclave at 121°C for 30min/ gamma 25kGy
- Volume Throughput (ml)
- 10ml
- Weight
- 0.19
- Wettability
- Hydrophobic
- Culture Vessel Filling - Equalizes pressure in sealed culture vessels by venting displaced air, keeping fill and drain lines fully closed.
- Sterile Tank Venting - Blocks aqueous ingress on storage tanks and carboys, letting sterile air and gas pass through the vent line.
- Organic Solvent Filtration - Wets readily with alcohols and mild hydrocarbons, delivering dependable clarification of organic solvent samples.
- Bioreactor Vent Protection - Repels water while venting bioreactors and fermenters, keeping process air and gases moving freely through the line.
- Beverage QC - Clarifies wine, beer, and juice samples ahead of HPLC testing for organic acids, sugars, and preservatives.
- Vial and Tubing Venting - Blocks liquid while venting sealed vials and tubing lines, keeping pressure equalized during fluid transfer steps.