    Polyvinylidene Fluoride (PVDF) Syringe Filters - SF14455

    Analytical laboratories processing organic samples in chromatography workflows face contamination risks from particulate matter that can damage expensive columns and compromise analytical precision, requiring filtration technology that removes particles without introducing extractables or leachables into critical solvent systems. Polyvinylidene fluoride membrane technology with 0.45 µm pore size addresses this challenge through hydrophobic surface chemistry that maintains compatibility with aggressive organic solvents while delivering efficient clarification performance. Additionally, the compact 13mm diameter design with 1.09 cm² filtration area and 10 µL holdup volume enables processing of 1-10 ml sample volumes while maximizing recovery of valuable analytical compounds and research materials through minimal retention characteristics.

    Key PVDF Membrane Characteristics

    • Hydrophobic nature requires pre-wetting with methanol, ethanol, or isopropanol before aqueous sample filtration, making this membrane ideal for organic mobile phase preparation
    • Superior chemical resistance withstands aggressive solvents including chlorinated compounds, ketones, esters, and aromatic hydrocarbons across diverse analytical chemistry applications
    • 0.45 µm pore size delivers reliable particulate removal for sample clarification in HPLC and GC-MS workflows without providing bacterial retention or sterile-grade specifications
    • Low protein binding characteristics preserve biomolecule concentration during pharmaceutical and biotechnology sample preparation, minimizing adsorption losses in critical assays
    • Thermal stability to 60°C with autoclave capability at 121°C provides sterilization options for contamination-sensitive analytical and research applications

    Key Construction Characteristics

    • 10 µL holdup volume optimizes yield by reducing sample retention within the housing, preserving valuable standards and analytical extracts in low-volume workflows
    • Polypropylene housing construction delivers reliable performance to 87 psi maximum operating pressure, providing structural integrity for pressurized filtration applications
    • Dual Luer-Lok and Luer-Slip connections integrate seamlessly with standard laboratory syringes without adapters, simplifying workflow setup in routine analytical environments
    • Integrated polypropylene prefilter captures large particulates upstream of the primary membrane, extending filter lifetime and reducing consumption in particulate-laden samples

    Laboratories processing small-volume analytical samples require clarification technology that combines broad solvent compatibility with minimal holdup and efficient particle removal. PVDF syringe filters deliver 0.45 µm clarification performance through hydrophobic membrane chemistry and integrated prefilter design. Engineered to overcome your analytical challenges, this filtration solution provides processing confidence via validated chemical resistance, compact design for sample conservation, and low protein binding for chromatography preparation and quality control applications requiring reliable particulate removal without sterile-grade capabilities.

    For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    5.8psi
    Connection Type
    Luer-Lok/ Luer Slip
    Diameter
    13mm
    Filtration Area
    1.09cm²
    Flow Rate
    8ml
    Holdup Volume
    10μL
    Material
    Polyvinylidene Fluoride (PVDF)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-130μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave at 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    10ml
    Wetability
    Hydrophobic
    • HPLC Mobile Phase Preparation - Clarifies organic and aqueous chromatography solvents for liquid chromatography, preventing column fouling in pharmaceutical analysis
    • GC Sample Clarification - Removes particles from analytical extracts before gas chromatography injection for accurate compound identification and quantification
    • Pharmaceutical QC Testing - Filters drug formulations and organic extracts for chromatographic analysis in quality control and stability testing programs
    • Environmental Extract Analysis - Clarifies soil and water extracts in organic solvents for pesticide and contaminant detection in regulatory compliance laboratories
    • Chemical Reagent Filtration - Processes analytical standards and solvent mixtures for research and manufacturing quality assurance applications
    • Polymer Solution Processing - Removes particulates from resin solutions and coating formulations for materials science research and industrial quality control