Chat with us, powered by LiveChat

Secure Checkout
PVDF Syringe Filters, 0.45um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

Thumbnail Filmstrip of PVDF Syringe Filters, 0.45um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk Images

    Purchase PVDF Syringe Filters, 0.45um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

    PVDF Syringe Filters, 0.45um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk
    Tisch SKU: SF14461

    $124.99
    In Stock
     

    Tisch Scientific PVDF Syringe Filters, 0.45 µm, 13 mm, 100/Pk - SF14461

    Tisch Scientific's product lineup extends from filtration membranes to devices and the consumable supplies laboratories use daily. Syringe filters span a wide range of membrane chemistries and pore sizes, so the format can be matched to the sample matrix and solvent system in use. PVDF resists HPLC mobile phases, alcohols, and mild hydrocarbons and clarifies samples at the rated pore size. Polyolefin construction sheds virtually no extractable material into the sample while holding its seal true run after run and routes flow to minimize backpressure in service. Where analytical results depend on clean samples, the preparation step stays consistent from sample to sample through a pre-tested syringe filter.

    Membrane Characteristics

    • Low ionic extractables preserve baseline stability in conductivity-based ion chromatography detection
    • Hydrophobic surface chemistry gives PVDF a water contact angle above 100 degrees, blocking wetting
    • Ethylene oxide sterilization cycles leave pore integrity and flow performance intact
    • Fluorinated polymer chemistry resists ozone, UV, and ionizing radiation
    • Cast membrane structure releases no fibers, unlike depth-media prefilters

    Housing Characteristics

    • PP housing supplied sterile in individual packaging for immediate use in aseptic filtration without bench preparation
    • Optimized internal geometry minimizes backpressure in service
    • Withstands ethylene oxide gas sterilization without embrittlement or structural damage
    • Rigid polypropylene body maintains its geometry through routine filtration pressure

    An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Standardize your filtration purchases across every method with volume pricing and documentation from the Tisch Scientific team.

    Sterilization Guidance

    Sterile single-use packaging removes any in-lab sterilization preparation step.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    5.8psi
    Connection Type
    Luer-Lok/Luer Slip
    Diameter
    13mm
    Filtration Area
    1.09cm²
    Flow Rate
    8ml
    Holdup Volume
    10μL
    Material
    Polyvinylidene Fluoride (PVDF)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-130μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Sterile
    Volume Throughput (ml)
    10ml
    Weight
    0.40
    Wettability
    Hydrophobic
    • Compressed Gas Filtration - Passes nitrogen and other inert gases freely while holding back moisture, protecting instruments and gas lines.
    • Organic Solvent Filtration - Wets readily with alcohols and mild hydrocarbons, delivering dependable clarification of organic solvent samples.
    • Vial and Tubing Venting - Blocks liquid while venting sealed vials and tubing lines, keeping pressure equalized during fluid transfer steps.
    • Bioreactor Vent Protection - Repels water while venting bioreactors and fermenters, keeping process air and gases moving freely through the line.
    • Dissolution Testing - Removes undissolved particles from timed USP 711 dissolution aliquots, preventing skewed potency and release results.
    • Culture Vessel Filling - Equalizes pressure in sealed culture vessels by venting displaced air, keeping fill and drain lines fully closed.