    Tisch Scientific PVDF Syringe Filters, 0.22 µm, 17 mm, 100/Pk - SF15614

    Tisch Scientific's sales team brings fast, courteous service to every filtration order, from first quote through fulfillment. A syringe filter with a hydrophobic vent-rated membrane keeps gas and vent lines free of microbial ingress. PVDF resists HPLC mobile phases, alcohols, and mild hydrocarbons while achieving sterile-grade retention at sub-micron pore sizes and blocks aqueous ingress in venting applications. Polypropylene construction maintains a low-dead-volume internal flow path and leaves no seam for sample to bypass the membrane. No separate sterilization cycle is needed when the gas path already runs through a validated sterile-grade membrane.

    Membrane Characteristics

    • Absolute pore rating ensures reproducible results between test runs
    • Cast membrane structure releases no fibers, unlike depth-media prefilters
    • Chemical compatibility spans the full pH 1 to 14 range
    • Bacterial challenge testing with Brevundimonas diminuta at 10 million CFU per cm2 confirms sterilizing grade
    • Autoclave sterilization cycles leave pore structure and flow performance intact

    Housing Characteristics

    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
    • Impact-tolerant polypropylene body withstands routine bench handling without damage
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion

    A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    14.5psi
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    17mm
    Filtration Area
    1.65cm²
    Flow Rate
    8ml
    Holdup Volume
    20μL
    Incompatibility
    Bases, esters, ethers, ketones, aqueous samples without rewetting
    Material
    Polyvinylidene Fluoride (PVDF)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-130μm
    Pack Count
    100
    Pore Size (µm)
    0.22
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave at 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    20ml
    Weight
    0.33
    Wettability
    Hydrophobic
    • Vial and Tubing Venting - Blocks liquid while venting sealed vials and tubing lines, keeping pressure equalized during fluid transfer steps.
    • Beverage QC - Clarifies wine, beer, and juice samples ahead of HPLC testing for organic acids, sugars, and preservatives.
    • Sterile Tank Venting - Blocks aqueous ingress on storage tanks and carboys, letting sterile air and gas pass through the vent line.
    • Dissolution Testing - Removes undissolved particles from timed USP 711 dissolution aliquots, preventing skewed potency and release results.
    • QuEChERS Extract Prep - Removes co-extracted waxes and pigments from QuEChERS extracts, protecting GC-MS and LC-MS systems during pesticide testing.
    • Culture Vessel Filling - Equalizes pressure in sealed culture vessels by venting displaced air, keeping fill and drain lines fully closed.