Chat with us, powered by LiveChat

Secure Checkout
PVDF Syringe Filters, 0.45um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of PVDF Syringe Filters, 0.45um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase PVDF Syringe Filters, 0.45um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    PVDF Syringe Filters, 0.45um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF15617

    $139.95
     

    Tisch Scientific PVDF Syringe Filters, 0.45 µm, 30 mm, 100/Pk - SF15617

    Tisch Scientific's sales team brings fast, courteous service to every filtration order, from first quote through fulfillment. Syringe filters span a wide range of membrane chemistries and pore sizes, so the format can be matched to the sample matrix and solvent system in use. PVDF holds up to alcohols and mild hydrocarbon solvents and repels water for dependable gas and vent filtration. Polypropylene construction maintains a low-dead-volume internal flow path while standing firm against aqueous acids, bases, and alcohols during regular handling and preserves sample chemistry across the flow path. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.

    Membrane Characteristics

    • Low ionic extractables preserve baseline stability in conductivity-based ion chromatography detection
    • Hydrophobic surface chemistry gives PVDF a water contact angle above 100 degrees, blocking wetting
    • Gamma irradiation sterilization causes no chain scission unlike polypropylene membranes
    • Absolute pore rating ensures reproducible results between test runs
    • Thin membrane structure sustains high flow for fast sample throughput

    Housing Characteristics

    • Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure
    • Impact-tolerant polypropylene body withstands routine bench handling without damage
    • Optimized internal geometry minimizes backpressure in service
    • Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping

    A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    5.8psi
    Connection Type
    Luer-Lok/Luer Slip
    Diameter
    30mm
    Filtration Area
    4.9cm²
    Flow Rate
    39ml
    Holdup Volume
    100μL
    Material
    Polyvinylidene Fluoride (PVDF)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-130μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave at 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    110ml
    Weight
    0.91
    Wettability
    Hydrophobic
    • Vial and Tubing Venting - Blocks liquid while venting sealed vials and tubing lines, keeping pressure equalized during fluid transfer steps.
    • Beverage QC - Clarifies wine, beer, and juice samples ahead of HPLC testing for organic acids, sugars, and preservatives.
    • QuEChERS Extract Prep - Removes co-extracted waxes and pigments from QuEChERS extracts, protecting GC-MS and LC-MS systems during pesticide testing.
    • Organic Solvent Filtration - Wets readily with alcohols and mild hydrocarbons, delivering dependable clarification of organic solvent samples.
    • Compressed Gas Filtration - Passes nitrogen and other inert gases freely while holding back moisture, protecting instruments and gas lines.
    • Petroleum Sample Prep - Removes particulates from fuel and lubricant samples ahead of viscosity and quality-control testing.