Chat with us, powered by LiveChat

Secure Checkout
PVDF Syringe Filters, 0.22um, 17mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

Thumbnail Filmstrip of PVDF Syringe Filters, 0.22um, 17mm, Luer-Lok/Luer Slip, Sterile, 100/Pk Images

    Purchase PVDF Syringe Filters, 0.22um, 17mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

    PVDF Syringe Filters, 0.22um, 17mm, Luer-Lok/Luer Slip, Sterile, 100/Pk
    Tisch SKU: SF18223

    $121.99
    Ships in 4 weeks
     

    Tisch Scientific PVDF Syringe Filters, 0.22 µm, 17 mm - SF18223

    Tisch Scientific holds its filtration pricing at levels that let budget-conscious laboratories stretch procurement dollars further. Each hydrophobic vent-rated filter carries manufacturer bacterial retention testing built into the design, letting a vent line stay in continuous service without repeating that testing on site between uses. Hydrophobic PVDF repels water for dependable gas and vent filtration while tolerating common chromatography solvents without degradation and achieves sterile-grade retention at sub-micron pore sizes. Polypropylene construction resists chemical degradation from routine sample matrices and holds its seal true run after run. No separate sterilization cycle is needed when the gas path already runs through a validated sterile-grade membrane.

    Membrane Characteristics

    • Hydrochloric, dilute nitric, and up to 90% sulfuric acid cause no attack
    • Fluorinated polymer chemistry resists ozone, UV, and ionizing radiation
    • Low extractables preserve a clean chromatographic baseline
    • Cast membrane structure releases no fibers, unlike depth-media prefilters
    • Absolute pore rating ensures reproducible results between test runs

    Housing Characteristics

    • Housing tolerates elevated-temperature aqueous and solvent sample filtration up to about 80°C without softening
    • Optimized internal geometry minimizes backpressure in service
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Resists stress cracking from aqueous salt and buffer solutions

    A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.

    Sterilization Guidance

    Sterile single-use packaging removes any in-lab sterilization preparation step.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    0.1psi.
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    17mm
    Filtration Area
    1.65cm²
    Flow Rate
    9ml/ min @ 10psi.
    Holdup Volume
    20µl
    Incompatibility
    Bases, esters, ethers, ketones, aqueous samples without rewetting
    Material
    Polyvinylidene Fluoride (PVDF)
    Maximum Operating Temperature (°C)
    100°C
    Pore Size (µm)
    0.22
    Sterility
    Sterile
    Volume Throughput (ml)
    20ml
    Weight
    0.70
    Wettability
    Hydrophobic
    • Organic Solvent Filtration - Wets readily with alcohols and mild hydrocarbons, delivering dependable clarification of organic solvent samples.
    • Dissolution Testing - Removes undissolved particles from timed USP 711 dissolution aliquots, preventing skewed potency and release results.
    • Bioreactor Vent Protection - Repels water while venting bioreactors and fermenters, keeping process air and gases moving freely through the line.
    • Beverage QC - Clarifies wine, beer, and juice samples ahead of HPLC testing for organic acids, sugars, and preservatives.
    • Vial and Tubing Venting - Blocks liquid while venting sealed vials and tubing lines, keeping pressure equalized during fluid transfer steps.
    • Sterile Tank Venting - Blocks aqueous ingress on storage tanks and carboys, letting sterile air and gas pass through the vent line.