Chat with us, powered by LiveChat
Secure Checkout
PVDF Syringe Filters, 0.45um, 20mm, Threaded Double Luer Lock, ABS Housing, Sterile, 100/Pk

Thumbnail Filmstrip of PVDF Syringe Filters, 0.45um, 20mm, Threaded Double Luer Lock, ABS Housing, Sterile, 100/Pk Images

    Purchase PVDF Syringe Filters, 0.45um, 20mm, Threaded Double Luer Lock, ABS Housing, Sterile, 100/Pk

    Tisch
    PVDF Syringe Filters, 0.45um, 20mm, Threaded Double Luer Lock, ABS Housing, Sterile, 100/Pk SKU: SPEC18223

    $185.94
    Ships in 4 weeks
     

    Polyvinylidene Fluoride (PVDF) Syringe Filters - SPEC18223

    Precision 0.45µm hydrophobic PVDF membrane construction with validated 4.35psi bubble point delivers sterile gamma-irradiated clarification in compact 20mm ABS housing optimized for small-volume organic solvent processing. Particulate removal protects analytical equipment from fouling without bacterial retention claims appropriate for clarification applications. Ready-to-use design with threaded double luer lock connection and 72.5psi operating pressure supports HPLC mobile phase preparation, chemical formulations, and environmental samples where space-efficient clarification combines with contamination-free processing and exceptional solvent compatibility.

    Key PVDF Membrane Characteristics

    • Hydrophobic surface requires alcohol pre-wetting before aqueous processing, activating the membrane for proper flow and preventing channeling that compromises filtration efficiency
    • Outstanding chemical stability withstands acetonitrile, methanol, chlorinated solvents, and aggressive organic reagents that rapidly degrade cellulosic and polyamide membrane alternatives
    • 0.45µm pore size removes particulates and protects analytical systems from fouling, providing clarification for organic solvents and chemical samples without bacterial retention
    • Ultra-low protein binding characteristics preserve biomolecule concentrations throughout clarification, preventing adsorptive losses that compromise recovery in your sample preparation workflows
    • Temperature tolerance to 80°C supports elevated-temperature sample processing while maintaining chemical compatibility across diverse pharmaceutical and chemical laboratory applications

    Key Construction Characteristics

    • ABS housing provides chemical resistance to common organic solvents while delivering mechanical strength for manual filtration operations in routine sample preparation
    • Threaded double luer lock connection creates secure, leak-proof attachment to syringes and transfer lines, preventing disconnection during processing workflows
    • 72.5psi maximum operating pressure accommodates manual syringe filtration and integration with low-pressure pumping systems for automated sample preparation
    • Sterile gamma-irradiated packaging delivers contamination-free clarification without requiring pre-use sterilization, streamlining workflows in pharmaceutical and biotechnology cleanroom environments

    Built to support your compact analytical workflows where space-constrained processing requires sterile clarification with broad organic solvent compatibility. PVDF's exceptional chemical stability handles the diverse solvent systems your laboratory encounters. Sterile individually-wrapped units maintain your contamination control standards while delivering the solvent resistance and particulate removal that protect analytical instrumentation, preserve sample integrity, and ensure reliable results across demanding HPLC, chemical analysis, and pharmaceutical applications where clarification capacity drives analytical success.

    For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    4.35psi
    Burst Pressure (psi)
    116psi
    Connection Type
    Double Luer Lock
    Construction
    Acrylonitrile Butadiene Styrene (ABS)
    Diameter
    20mm
    Dimensions (W x D x H)
    23mmx25.2mm
    Material
    Polyvinylidene Fluoride (PVDF)
    Maximum Operating Pressure
    72.5psi
    Maximum Operating Temperature (°C)
    80℃
    Pack Count
    100
    Pore Size (µm)
    0.45
    Sterility
    Sterile
    Weight
    0.72
    Wetability
    Hydrophobic
    • HPLC Mobile Phase Clarification — Remove particulates from organic mobile phases, protecting columns and extending service life in chromatographic workflows
    • Organic Solvent Filtration — Process acetonitrile, methanol, and chemical reagents where solvent resistance maintains membrane performance
    • LC-MS Sample Preparation — Clarify biological extracts and chemical standards, protecting mass spectrometry ionization sources from particulates
    • Chemical Formulation Processing — Filter pharmaceutical intermediates and specialty chemicals where clarification protects downstream processing
    • Environmental Sample Preparation — Clarify organic extracts from soil and water samples, removing suspended solids before chromatographic analysis
    • Quality Control Testing — Prepare samples for routine analytical testing where sterile packaging eliminates contamination risks