    Tisch Scientific Polypropylene (PP) Syringe Filters, 0.45 µm, 25 mm, 100/Pk - SF18306

    Tisch Scientific reduces per-unit costs for laboratories that place blanket purchase agreements or large-quantity orders. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. The hydrophobic polypropylene matrix repels water in vent and solvent service while sustaining throughput as a depth medium and tolerates solvents and acids that degrade many membranes. The polypropylene housing presses snugly against the membrane during the pass while staying inert across common laboratory solvents and sheds virtually no extractable material into the sample. Where analytical results depend on clean samples, the preparation step stays consistent from sample to sample through a pre-tested syringe filter.

    Prefiltration

    • Two-stage construction with the prefilter ahead of the final membrane
    • High dirt-holding capacity for the heaviest particulate loads
    • Nominal depth rating sized for coarse particulate capture
    • Layered glass fiber and polypropylene depth media

    Membrane Characteristics

    • Operating pressure reaches 72 psi with a burst rating near 116 psi
    • Alcohol pre-wetting opens the hydrophobic matrix to aqueous sample streams
    • Wets through readily under modest differential pressure despite an inherently hydrophobic surface
    • Low binding throughout the depth matrix preserves dilute analyte concentration
    • Halogen-free composition avoids hazardous fluorine byproducts during incineration

    Housing Characteristics

    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
    • Standardized luer connection geometry provides secure engagement with standard syringe tips
    • Polypropylene housing withstands rated backpressure from dense sample matrices without deformation

    Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Request comparable filtration options that may offer cost savings for your order from the Tisch Scientific team.

    Sterilization Guidance

    Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    7.40psi
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    35ml
    Holdup Volume
    400μL
    Material
    Polypropylene (PP)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    140-260μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP+GF+PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    50ml
    Weight
    0.52
    Wettability
    Hydrophobic
    • Pharmaceutical Dissolution Prep - Clarifies dissolution medium samples in acidic aqueous and buffered media as a prefilter for HPLC assay.
    • Dilute Acid Sample Prep - Withstands dilute hydrochloric and sulfuric acid streams, enabling acidic sample preparation without membrane attack.
    • Textile Dye Wastewater - Processes aqueous and alcohol-containing dye effluents for absorbance monitoring and color removal tracking.
    • Industrial Solvent Monitoring - Clarifies organic solvent process streams and used-solvent recovery batches for quality and contamination analysis.
    • DMF Sample Filtration - Handles N,N-dimethylformamide polymer and pharmaceutical solutions with full chemical resistance for routine analytical prep.
    • Alcohol Solution Filtration - Clarifies methanol, ethanol, and isopropanol solutions for HPLC and GC analysis without swelling.