Tisch Scientific PTFE Syringe Filters, 0.1 µm, 33 mm, 100/Pk - SF18080
Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. A sterilizing-grade syringe filter carries manufacturer bacterial retention testing built into the design, giving analysts documented sterile-grade performance without repeating that testing in-house for the format. The PTFE membrane withstands aggressive organics that degrade other media while delivering sterilizing-grade liquid retention at sub-micron pore sizes and accepts aqueous samples without alcohol pre-wetting. The polypropylene housing holds its seal true run after run while sustaining efficient flow on viscous samples and sheds virtually no extractable material into the sample. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Membrane Characteristics
- Stable across a wide operating temperature range for demanding methods
- Validated against a liquid suspension Brevundimonas diminuta challenge at 10 million CFU per square centimeter
- UL 94 V-0 rating confirms the highest self-extinguishing classification
- Inert composition offers no nutrient source for microbial growth
- Low extractables keep the chromatographic background clean
Housing Characteristics
- Standardized luer connection geometry provides secure engagement with standard syringe tips
- Rigid polypropylene body maintains its geometry through routine filtration pressure
- Minimal extractable release from the housing supports sensitive analytical work downstream
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
A particulate-laden aqueous sample makes the rest of your preparation unpredictable. Consistent aqueous clarification clears particulates without slowing your bench routine from the first sample of the day through the last. Request a quote on bulk pricing for larger filtration orders from the Tisch Scientific team.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 29psi
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 33mm
- Filtration Area
- 4.6cm²
- Flow Rate
- 12ml
- Holdup Volume
- 100μL
- Incompatibility
- Bases, esters, ethers, ketones
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.1
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- GF
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 110ml
- Weight
- 0.96
- Wettability
- Hydrophilic
- Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
- Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
- Toxicology Screening - Clarifies protein-precipitated serum, plasma, and urine extracts ahead of LC-MS or GC-MS drug screening analysis.