Tisch Scientific's product lineup extends from filtration membranes to devices and the consumable supplies laboratories use daily. Each hydrophobic vent-rated filter carries manufacturer bacterial retention testing built into the design, letting a vent line stay in continuous service without repeating that testing on site between uses. Hydrophobic PTFE delivers sterilizing-grade gas and vent filtration at the rated pore size and filters aggressive organic solvents without breakdown. The polypropylene housing resists aqueous acids, bases, and alcohols in routine use while sustaining efficient flow on viscous samples and holds its seal true run after run. A vent or gas line stays free of airborne bacteria once a hydrophobic, sterilizing-grade membrane is in the path.
Membrane Characteristics
- High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
- Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
- Surface energy near 18.5 dynes per centimeter repels oils and nonpolar liquids
- Node-fibril microstructure resists compaction under sustained operating pressure
- Ionic and metallic extractable levels stay very low
Housing Characteristics
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Rigid polypropylene body maintains its geometry through routine filtration pressure
- Resists stress cracking from aqueous salt and buffer solutions
- Impact-tolerant polypropylene body withstands routine bench handling without damage
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Reliable solvent prefiltration keeps a stray particulate from carrying into your downstream work before it carries into further processing. Contact Tisch Scientific for a quote, lead time, or stock-on-hand check on your filtration product selection.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 17.4(absolute ethyl alcohol )
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 30mm
- Filtration Area
- 4.9cm²
- Flow Rate
- 29.5ml
- Holdup Volume
- 100μL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 120ml
- Weight
- 0.91
- Wettability
- Hydrophobic
- Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
- Cryogenic Fluids - Delivers consistent performance across extreme temperature ranges, filtering cryogenic liquids with dependable, reliable results.
- Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
- Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.