Tisch Scientific PTFE Syringe Filters, 0.22 µm, 30 mm, 100/Pk - SF18323
Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. Each hydrophobic vent-rated filter carries manufacturer bacterial retention testing built into the design, letting a vent line stay in continuous service without repeating that testing on site between uses. Hydrophobic PTFE blocks aqueous ingress in vent and gas applications and suits solvent filtration where other membranes fail. The polypropylene housing resists aqueous acids, bases, and alcohols in routine use while providing a factory-sterilized fluid path suited to aseptic sample preparation and presses snugly against the membrane during the pass. No separate sterilization cycle is needed when the gas path already runs through a validated sterile-grade membrane.
Membrane Characteristics
- Non-wetting pore surface blocks liquid water while passing water vapor freely
- Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
- Chemical resistance spans the full pH 1 to 14 range
- Non-fibrous, fully synthetic structure sheds no fibers into filtrate
- Stable across a wide operating temperature range for demanding methods
Housing Characteristics
- Minimal extractable release from the housing supports sensitive analytical work downstream
- The seal formed against the membrane blocks bypass at rated operating pressure
- Withstands standard 121°C steam autoclave cycles without softening or structural distortion
- Resists stress cracking from aqueous salt and buffer solutions
An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Standardize your filtration purchases across every method with volume pricing and documentation from the Tisch Scientific team.
Sterilization Guidance
Factory sterilization supports immediate use in workflows where sterility assurance matters.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 17.4(absolute ethyl alcohol )
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 30mm
- Filtration Area
- 4.9cm²
- Flow Rate
- 29.5ml
- Holdup Volume
- 100μL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Sterility
- Sterile
- Volume Throughput (ml)
- 120ml
- Weight
- 1.40
- Wettability
- Hydrophobic
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
- Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
- Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.