Chat with us, powered by LiveChat

Secure Checkout
PTFE Syringe Filters, 1.0um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of PTFE Syringe Filters, 1.0um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase PTFE Syringe Filters, 1.0um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    Tisch
    PTFE Syringe Filters, 1.0um, 30mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk SKU: SF18324

    $144.95
    Only 6 in stock. Order now!
     

    Polytetrafluoroethylene (PTFE) Syringe Filters - SF18324

    Featuring hydrophobic PTFE membrane technology with 1.0µm pore size for reliable particle removal and sample clarification in aggressive solvent systems. Large 30mm diameter filters deliver efficient 85ml flow rates while maintaining consistent retention of fine particulates and suspended matter. Polypropylene housing construction ensures robust performance at pressures up to 87psi across diverse laboratory applications.

    Key Polytetrafluoroethylene (PTFE) Membrane Characteristics

    • Hydrophobic membrane design effectively filters organic solvents, acids, and bases without chemical interaction
    • Precision 1.0µm pore size removes fine particles, suspended solids, and microbial contaminants from solutions
    • Exceptional chemical resistance from strong carbon-fluorine bonds maintains stability in caustic environments
    • Membrane thickness of 80-140µm balances optimal flow rates with superior particle retention capabilities
    • Autoclavable at 121°C for 30 minutes or gamma sterilizable at 25kGy for contamination-free processing

    Key Construction Characteristics

    • Polypropylene housing provides broad chemical compatibility with aggressive solvents and reagents
    • Large 30mm diameter offers 4.9cm² filtration area for efficient processing of high-volume samples
    • Holdup volume of 100µL minimizes sample loss while maintaining practical handling characteristics
    • Luer-Lok/Luer Slip dual connection system ensures secure attachment to various syringe sizes

    SF18324 filters optimize your sample preparation workflow with an 85ml flow rate that balances throughput with exceptional particle retention. Large 30mm diameter configuration enables rapid processing while your samples maintain integrity at operating temperatures up to 60°C. Bubble point verification at 4.35psi using absolute ethyl alcohol confirms consistent membrane pore structure for reproducible filtration results across the 120ml volume throughput capacity.

    For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    4.35(absolute ethyl alcohol )
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    30mm
    Filtration Area
    4.9cm²
    Flow Rate
    85ml
    Holdup Volume
    100μL
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    1.0
    Sterility
    NonSterile
    Sterilization
    Autoclave 121°C for 30min/ Gamma 25kGy
    Volume Throughput (ml)
    120ml
    Weight
    0.91
    Wetability
    Hydrophobic
    • Sample Clarification Processing - Clarifies organic solvents by removing heavy particulates to protect sensitive analytical instrumentation
    • HPLC Sample Pre-filtration - Acts as a robust pre-filter for heavily particle-laden samples to extend the life of downstream analytical columns
    • Viscous Media Filtration - Clarifies viscous organic fluids and polymer solutions by utilizing the larger 30mm filtration surface area
    • Biological Extract Clarification - Clarifies organic solvent-based biological extracts and tissue samples for downstream analysis or purification
    • Environmental Extract Processing - Reliably filters organic extracts from soil and water samples for pesticide analysis and environmental monitoring
    • Pharmaceutical Prefiltration Processing - Reduces bioburden and particulate load in solutions before final sterilization steps in production