LabExact Tri-Layer PVDF Syringe Filters, 0.22 µm, 25 mm, 100/Pk - LE-IWT-ES10406
A single-use hydrophobic vent filter reaches sterilizing-grade retention on a vent line without the autoclave cycle or in-line housing a reusable gas filtration setup would require. Hydrophobic PVDF repels water for dependable gas and vent filtration while providing sterilizing-grade retention at sub-micron pore sizes and holds up to alcohols and mild hydrocarbon solvents. Polypropylene construction maintains a low-dead-volume internal flow path and presses snugly against the membrane during the pass. A vent or gas line stays free of airborne bacteria once a hydrophobic, sterilizing-grade membrane is in the path.
Membrane Characteristics
- Fluorinated polymer chemistry resists ozone, UV, and ionizing radiation
- Fluoropolymer chemistry resists microbial and fungal degradation
- Vapor-phase hydrogen peroxide decontamination cycles leave the membrane intact
- Organic solvent resistance beats PES or nylon at comparable pore size
- Cast membrane structure releases no fibers, unlike depth-media prefilters
Housing Characteristics
- Plasticizer-free polyolefin construction keeps the fluid path clean
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
- Translucent housing wall allows visual confirmation of sample flow during filtration
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Request a quote on bulk pricing for larger filtration orders from the Tisch Scientific team.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Diameter
- 25mm
- Material
- Polyvinylidene Fluoride (PVDF)
- Pack Count
- 100
- Pore Size (µm)
- 0.22
- Sterility
- Nonsterile
- Weight
- 0.168
- Wettability
- Hydrophobic
- Whatman Equivalent
- 6872-2502
- QuEChERS Extract Prep - Removes co-extracted waxes and pigments from QuEChERS extracts, protecting GC-MS and LC-MS systems during pesticide testing.
- Dissolution Testing - Removes undissolved particles from timed USP 711 dissolution aliquots, preventing skewed potency and release results.
- Sterile Tank Venting - Blocks aqueous ingress on storage tanks and carboys, letting sterile air and gas pass through the vent line.
- Compressed Gas Filtration - Passes nitrogen and other inert gases freely while holding back moisture, protecting instruments and gas lines.
- Bioreactor Vent Protection - Repels water while venting bioreactors and fermenters, keeping process air and gases moving freely through the line.
- Vial and Tubing Venting - Blocks liquid while venting sealed vials and tubing lines, keeping pressure equalized during fluid transfer steps.