Qualitative Filter Paper - 90mm, 100/pk - CF15032
Tisch Scientific rewards laboratories with special pricing when they commit to standing or high-quantity purchasing arrangements. The qualitative grade carries no controlled ash ceiling, unlike the ashless grades reserved for gravimetric work. Qualitative cellulose paper offers a naturally hydrophilic surface that wets on contact and captures particulates across routine gravity and vacuum filtration. Where analytical results depend on a clean, repeatable separation, sample-prep reproducibility stays intact from one sheet to the next without switching to a premium grade.
Filter Paper Characteristics
- A 7 to 15 micron nominal retention band for standard suspended solids
- Basis weight between 30 and 97 grams per square meter
- Naturally hydrophilic cellulose wets on contact without conditioning
- Hot filtration compatible for clarifying solutions near boiling
- Neutral, chemically untreated surface for general sample preparation
- Fast flow rate accelerates clarification of large sample volumes
Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine from the first sample of the day through the last. Request a quality certificate or lot documentation on your order from our support team, any time.
- Capacity
- 1mL
- Diameter
- 90mm
- Flow Speed
- Medium Fast
- Folded/ Fluted/ Pleated
- No
- Hardened (Yes/ No)
- No
- Material
- Cellulose
- Nominal Ash Content (%)
- ≤0.15%
- Nominal Basis Weight (g/ m²)
- 80±5g/m²
- Pack Count
- 100
- Particle Retention
- 11um
- Pore Size (µm)
- 11
- Qualitative/ Quantitative
- Qualitative
- Sterility
- Nonsterile
- Weight
- 0.13
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Gravity Filtration - Clarifies aqueous samples in funnels for routine bench separations without specialized vacuum equipment or setup.
- Food and Beverage QC - Clarifies juices, wines, and food extracts to remove pulp and debris before quality-control analysis steps.
- Chemical Indicator Testing - Changes color on contact with compounds like hydrogen sulfide gas when impregnated with reagents such as lead acetate.
- Soil and Water Testing - Filters environmental soil slurries and water samples to remove sediment before routine analytical measurement.
- Sample Clarification - Removes coarse particulates from solutions ahead of analysis, protecting instruments and improving sample clarity.
- Teaching Laboratories - Provides economical, reliable filtration for student experiments and routine instructional separation exercises.