Quantitative Filter Paper - 180mm, 100/pk - CF15005
From devices to consumables, the Tisch Scientific catalog spans a wide range of laboratory product lines. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. Ashless grade paper seats cleanly in funnels for gravimetric filtration steps while keeping chemical background low for critical gravimetric methods and retains particulates at a fine, gravimetric-grade cutoff. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Fast flow rate accelerates filtration of large sample volumes
- Basis weight between 75 and 96 grams per square meter
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Compatible with hot filtration in gravimetric workflows
- Rated ash content of 0.01 percent or below
- Ignites completely on combustion
A filter that contributes mass of its own puts a blank correction between you and the analyte you set out to weigh. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. Request a quality certificate or lot documentation on your order from our support team, any time.
- Capacity
- 0.3mL
- Diameter
- 180mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Hardened (Yes/ No)
- No
- Material
- Cellulose
- Nominal Ash Content (%)
- ≤0.011%
- Nominal Basis Weight (g/ m²)
- 80±5g/m²
- Pack Count
- 100
- Particle Retention
- 20-25um
- Pore Size (µm)
- 20.0-25.0
- Qualitative/ Quantitative
- Quantitative Ashless
- Sterility
- Nonsterile
- Weight
- 0.56
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Low-Ash Gravimetric Work - Grades rated at 0.01 percent ash or below hold filter bias within routine quantitative tolerances.