Quantitative Filter Paper - 125mm, 100/pk - CF15009
Tisch Scientific trims the friction out of buying, fielding requests for cost estimates and product details without unnecessary delay. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. The ashless grade retains particulates at a fine, gravimetric-grade cutoff while keeping chemical background low for critical gravimetric methods and seats cleanly in funnels for gravimetric filtration steps. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Fast flow rate accelerates filtration of large sample volumes
- Ignites completely on combustion
- Compatible with hot filtration in gravimetric workflows
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Leaves negligible carbon residue
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue as the crucible comes to constant weight. Request blanket-order pricing for your routine laboratory orders from the Tisch Scientific team.
- Capacity
- 1.5mL
- Diameter
- 125mm
- Flow Speed
- Medium Fast
- Folded/ Fluted/ Pleated
- No
- Hardened (Yes/ No)
- No
- Material
- Cellulose
- Nominal Ash Content (%)
- ≤0.011%
- Nominal Basis Weight (g/ m²)
- 80±5g/m²
- Pack Count
- 100
- Particle Retention
- 16um
- Pore Size (µm)
- 16
- Qualitative/ Quantitative
- Quantitative Ashless
- Sterility
- Nonsterile
- Weight
- 0.53
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Low-Ash Gravimetric Work - Grades rated at 0.01 percent ash or below hold filter bias within routine quantitative tolerances.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.