Quantitative Filter Paper - 150mm, 100/pk - CF15010
Tisch Scientific selects filtration suppliers with proven production track records for consistent manufacturing quality. Ashless grade filter paper anchors gravimetric analysis workflows in pharma, biotech, and environmental laboratories. The ashless grade retains particulates at a fine, gravimetric-grade cutoff while seating cleanly in funnels for gravimetric filtration steps and keeps chemical background low for critical gravimetric methods. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Leaves negligible carbon residue
- Adds no measurable mass to a gravimetric determination
- Ignites completely on combustion
- Rated ash content of 0.01 percent or below
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. Request blanket-order pricing for your routine laboratory orders from the Tisch Scientific team.
- Capacity
- 20mL
- Diameter
- 150mm
- Flow Speed
- Medium Fast
- Folded/ Fluted/ Pleated
- No
- Hardened (Yes/ No)
- No
- Material
- Cellulose
- Nominal Ash Content (%)
- ≤0.011%
- Nominal Basis Weight (g/ m²)
- 80±5g/m²
- Pack Count
- 100
- Particle Retention
- 16um
- Pore Size (µm)
- 16
- Qualitative/ Quantitative
- Quantitative Ashless
- Sterility
- Nonsterile
- Weight
- 0.58
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Low-Ash Gravimetric Work - Grades rated at 0.01 percent ash or below hold filter bias within routine quantitative tolerances.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.