Quantitative Filter Paper - 70mm, 100/pk - CF15012
Tisch Scientific connects buyers with a responsive sales team for fast quotes, stock checks, and order support across the filtration catalog. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. Ashless cellulose construction keeps chemical background low for critical gravimetric methods while seating cleanly in funnels for gravimetric filtration steps and retains particulates at a fine, gravimetric-grade cutoff. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Medium flow rate balances retention and throughput for routine ashless filtration
- Ignites completely on combustion
- Compatible with hot filtration in gravimetric workflows
- Basis weight between 75 and 96 grams per square meter
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Rated ash content of 0.01 percent or below
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue as the crucible comes to constant weight. Contact the Tisch Scientific team any time you need volume pricing, order status, or documentation on a product order.
- Capacity
- 350uL
- Diameter
- 70mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Hardened (Yes/ No)
- No
- Material
- Cellulose
- Nominal Ash Content (%)
- ≤0.011%
- Nominal Basis Weight (g/ m²)
- 80±5g/m²
- Pack Count
- 100
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative Ashless
- Sterility
- Nonsterile
- Weight
- 0.26
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Low-Ash Gravimetric Work - Grades rated at 0.01 percent ash or below hold filter bias within routine quantitative tolerances.