Quantitative Filter Paper - 90mm, 100/pk - CF15013
From devices to consumables, the Tisch Scientific catalog spans a wide range of laboratory product lines. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. Ashless grade paper seats cleanly in funnels for gravimetric filtration steps and keeps chemical background low for critical gravimetric methods. When a gravimetric determination depends on the filter itself adding no measurable mass, the ashless grade's controlled ash ceiling keeps that determination valid.
Filter Paper Characteristics
- Adds no measurable mass to a gravimetric determination
- Basis weight between 75 and 96 grams per square meter
- Ignites completely on combustion
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Rated ash content of 0.01 percent or below
- Leaves negligible carbon residue
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue so a small, known paper blank is all you correct for. Not sure which product fits your order? Request a quote and current stock from the Tisch Scientific team.
- Capacity
- 350uL
- Diameter
- 90mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Hardened (Yes/ No)
- No
- Material
- Cellulose
- Nominal Ash Content (%)
- ≤0.011%
- Nominal Basis Weight (g/ m²)
- 80±5g/m²
- Pack Count
- 100
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative Ashless
- Sterility
- Nonsterile
- Weight
- 0.13
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Low-Ash Gravimetric Work - Grades rated at 0.01 percent ash or below hold filter bias within routine quantitative tolerances.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.