Tisch Scientific PTFE Syringe Filters, 0.45 µm, 13 mm, 100/Pk - SF18099
Tisch Scientific makes the ordering process straightforward, turning around requests for pricing and product information fast. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. PTFE suits solvent and reagent filtration where other membranes fail and clarifies solvent streams at the rated pore size. The polypropylene housing preserves sample chemistry across the flow path while leaving no seam for sample to bypass the membrane and maintains a low-dead-volume internal flow path. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.
Membrane Characteristics
- Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
- Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
- Solvent tolerance includes full-strength tetrahydrofuran and chlorinated solvents such as dichloromethane
- Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
- High porosity minimizes hold-up volume for small sample volumes
Housing Characteristics
- Impact-tolerant polypropylene body withstands routine bench handling without damage
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
- Stable across the full aqueous pH range in routine sample work
- Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure
Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine from the first sample of the day through the last. Request blanket-order pricing and paperwork support for your routine filtration purchases.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 21.75psi
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 13mm
- Filtration Area
- 1.09cm²
- Flow Rate
- 11ml
- Holdup Volume
- 10μL
- Incompatibility
- Bases, esters, ethers, ketones
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- PP
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 10ml
- Weight
- 0.19
- Wettability
- Hydrophilic
- Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
- Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.
- Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.