Tisch Scientific Polypropylene (PP) Syringe Filters, 20 µm, 25 mm, 100/Pk - SPEC20218
Tisch Scientific vets its filtration partners carefully, favoring those with a consistent record of dependable output. A macro-porosity screen stage protects finer downstream filters and process equipment from premature clogging caused by visible debris and coarse aggregates. Polypropylene keeps binding low while capturing particulates through its depth while resisting a broad range of organic solvents, acids, and bases in service and combines water-repelling character with wide chemical durability. The PP housing stays inert across common laboratory solvents and buffers in routine use while shedding virtually no extractable material into the sample and presses snugly against the membrane during the pass. When gross particulates or aggregates threaten to clog tubing or foul a pump, upstream coarse screening keeps the downstream path open and the process running without interruption.
Membrane Characteristics
- Saturated hydrocarbon backbone resists the hydrolytic degradation common in ester-linked filter media
- Nominal depth matrix distributes particulate load progressively through the medium volume
- Dense polypropylene fiber network intercepts fine particles through the full medium depth
- Operating pressure reaches 72 psi with a burst rating near 116 psi
- PP/PE depth medium tolerates progressive particle accumulation as dirt-holding capacity fills
Housing Characteristics
- Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure
- Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
- Standardized luer connection geometry provides secure engagement with standard syringe tips
- Thermal-bonded construction keeps adhesives out of the fluid path
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 4.08cm²
- Flow Rate
- 300ml
- Holdup Volume
- 100μL
- Incompatibility
- Esters, hexane, toluene, benzene, dichloromenthan
- Material
- Polypropylene (PP)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 140-260μm
- Pack Count
- 100
- Pore Size (µm)
- 20.0
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclave 121°C for 30min/ gamma 25kGy
- Volume Throughput (ml)
- 50ml
- Weight
- 0.52
- Wettability
- Hydrophobic
- Adhesive and Resin Analysis - Clarifies adhesive and polymer resin solutions in alcohol and aliphatic solvent media for quality and additive assay.
- General Lab Use - Supports the clarification of diverse solvent-based and process liquid streams, providing a reliable and cost-effective solution.
- Mineral Acid Compatibility - Withstands concentrated hydrochloric acid and strong caustic bases in aqueous inorganic extraction workflows.
- Polymer Solution Prep - Handles THF and alcohol polymer solutions with high loads for GPC and SEC column protection and sample clarification.
- DMSO Solution Handling - Filters dimethyl sulfoxide preparations and drug formulations without the membrane degradation of less resistant polymers.
- Dilute Acid Sample Prep - Withstands dilute hydrochloric and sulfuric acid streams, enabling acidic sample preparation without membrane attack.