PES Syringe Filters, 0.1um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of PES Syringe Filters, 0.1um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase PES Syringe Filters, 0.1um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    PES Syringe Filters, 0.1um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF18067

    $105.95
     

    Tisch Scientific Polyethersulfone (PES) Syringe Filters, 0.1 µm, 13 mm, 100/Pk - SF18067

    Tisch Scientific's sales team brings fast, courteous service to every filtration order, from first quote through fulfillment. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. The PES membrane delivers bacterial retention at the rated pore size and keeps that modified surface active throughout use. The polypropylene housing presses snugly against the membrane during the pass and resists degradation from routine sample matrices. When sample preparation calls for a sterile filtrate at the point of injection, sterilizing-grade absolute retention delivers it directly, protecting the analytical method from microbial interference.

    Membrane Characteristics

    • Mycoplasma retention at the 0.1 micron rating is validated
    • Ionic extractables from the membrane stay very low
    • Antibody and protein samples pass through PES with minimal adsorptive loss
    • Inherent hydrophilicity allows instant aqueous wetting with no pre-wetting step
    • DNA and RNA pass through with negligible adsorptive loss

    Housing Characteristics

    • Medical-grade polypropylene with broad chemical compatibility
    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Standardized luer connection geometry provides secure engagement with standard syringe tips

    An unfiltered buffer can foul your instrument and interrupt a run mid-sequence. Reliable particulate removal protects your instruments and your data so column life and baseline stability stay predictable. Request blanket-order pricing and paperwork support for your routine filtration purchases.

    Sterilization Guidance

    Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    26.11psi
    Burst Pressure (psi)
    87psi
    Connection Type
    Luer-Lok/Luer Slip
    Diameter
    13mm
    Filtration Area
    1.09cm²
    Flow Rate
    3.5ml
    Holdup Volume
    10μL
    Material
    Polyethersulfone (PES)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-160μm
    Pack Count
    100
    Pore Size (µm)
    0.1
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    10ml
    Weight
    0.19
    Wettability
    Hydrophilic
    • Sample Recovery - Minimizes sample loss in low-protein-binding applications, delivering high yield for precious or rare biological specimens.
    • Organic Carbon Testing - Clarifies water samples ahead of DOC and UV254 analysis while keeping organic carbon adsorption to the membrane minimal.
    • Media Preparation - Facilitates rapid sterilization of tissue culture additives, lowering contamination risk during sensitive laboratory work.
    • Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.
    • Pesticide Residue Testing - PES membranes improve polar pesticide recovery in food-safety LC-MS/MS testing versus hydrogen-bonding nylon.
    • Cell Culture - Reduces the risk of mycoplasma contamination in growth media, supporting healthier cell lines and more reliable experimental outcomes.