Tisch Scientific PTFE Syringe Filters, 0.1 µm, 33 mm, 100/Pk - SF18075
Tisch Scientific makes the ordering process straightforward, turning around requests for pricing and product information fast. A sterilizing-grade syringe filter delivers point-of-use sterile filtration in a single-use format, without the housing and gasket maintenance a reusable stainless steel filter holder requires. PTFE filters aggressive organic solvents without swelling or breakdown and combines aqueous wetting with broad solvent resistance. The PP housing stays inert across common laboratory solvents and buffers in routine use while maintaining a low-dead-volume internal flow path and delivers a chemically clean filtrate to the downstream step. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Membrane Characteristics
- Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
- Aqueous buffers and HPLC mobile phases wet the hydrophilic surface instantly
- Inert composition offers no nutrient source for microbial growth
- Biological inertness resists enzymatic attack from proteases and lipases
- UL 94 V-0 rating confirms the highest self-extinguishing classification
Housing Characteristics
- Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure
- Impact-tolerant polypropylene body withstands routine bench handling without damage
- Medical-grade polypropylene with broad chemical compatibility
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
Unfiltered particulates shift your retention times and peak shapes from run to run. Pre-injection filtration protects the resolution your methods depend on so your retention times and peak shapes stay consistent. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 29psi
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 33mm
- Filtration Area
- 4.6cm²
- Flow Rate
- 12ml
- Holdup Volume
- 100μL
- Incompatibility
- Bases, esters, ethers, ketones
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.1
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- PP
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 110ml
- Weight
- 0.96
- Wettability
- Hydrophilic
- Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.