Tisch Scientific PTFE Syringe Filters, 0.1 µm, 25 mm, 100/Pk - SF18088
Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. Gas and vent service calls for a hydrophobic syringe filter rated to the same sterilizing-grade pore size as its liquid counterpart. PTFE suits solvent and reagent filtration where other membranes fail while repelling water and passing gases and solvents freely and provides bacterial retention in gas and vent streams. Low-extractable polypropylene keeps sample purity intact through the filtration pass and arrives factory-sterilized and individually sealed for sterile use. No separate sterilization cycle is needed when the gas path already runs through a validated sterile-grade membrane.
Membrane Characteristics
- High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
- High porosity minimizes hold-up volume for small sample volumes
- Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
- Node-fibril microstructure resists compaction under sustained operating pressure
- Chemical resistance spans the full pH 1 to 14 range
Housing Characteristics
- Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
- Minimal extractable release from the housing supports sensitive analytical work downstream
- Thermal-bonded construction keeps adhesives out of the fluid path
- Translucent housing wall allows visual confirmation of sample flow during filtration
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Request available pack sizes and lead times across this filtration line's membrane options from the Tisch Scientific team.
Sterilization Guidance
Factory sterilization supports immediate use in workflows where sterility assurance matters.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 26.11(absolute ethyl alcohol)
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 25mm
- Filtration Area
- 4.08cm²
- Flow Rate
- 10ml
- Holdup Volume
- 100μL
- Incompatibility
- Aqueous samples without rewetting
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 0.1
- Sterility
- Sterile
- Volume Throughput (ml)
- 100ml
- Weight
- 0.88
- Wettability
- Hydrophobic
- Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
- Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
- Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
- Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
- Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
- Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.