Chat with us, powered by LiveChat

Secure Checkout
PTFE Syringe Filters, 0.1um, 33mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

Thumbnail Filmstrip of PTFE Syringe Filters, 0.1um, 33mm, Luer-Lok/Luer Slip, Sterile, 100/Pk Images

    Purchase PTFE Syringe Filters, 0.1um, 33mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

    PTFE Syringe Filters, 0.1um, 33mm, Luer-Lok/Luer Slip, Sterile, 100/Pk
    Tisch SKU: SF18089

    $226.95
     

    Tisch Scientific PTFE Syringe Filters, 0.1 µm, 33 mm, 100/Pk - SF18089

    Tisch Scientific vets its filtration partners carefully, favoring those with a consistent record of dependable output. Gas and vent service calls for a hydrophobic syringe filter rated to the same sterilizing-grade pore size as its liquid counterpart. PTFE filters aggressive organic solvents without swelling or breakdown and provides bacterial retention in gas and vent streams. The polypropylene housing holds its seal true run after run and routes flow to minimize backpressure in service. A vent or gas line stays free of airborne bacteria once a hydrophobic, sterilizing-grade membrane is in the path.

    Membrane Characteristics

    • Inert composition offers no nutrient source for microbial growth
    • Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
    • Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
    • Non-wetting pore surface blocks liquid water while passing water vapor freely
    • Stable across a wide operating temperature range for demanding methods

    Housing Characteristics

    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
    • Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
    • Thermal-bonded construction keeps adhesives out of the fluid path
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate

    An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Request blanket-order pricing and paperwork support for your routine filtration purchases.

    Sterilization Guidance

    Sterile single-use packaging removes any in-lab sterilization preparation step.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    26.11psi (absolute ethyl alcohol)
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    33mm
    Filtration Area
    4.6cm²
    Flow Rate
    12ml
    Holdup Volume
    100μL
    Incompatibility
    Aqueous samples without rewetting
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    0.1
    Sterility
    Sterile
    Volume Throughput (ml)
    120ml
    Weight
    1.46
    Wettability
    Hydrophobic
    • Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
    • Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
    • Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
    • Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
    • Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
    • Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.