Tisch Scientific PTFE Syringe Filters, 1 µm, 13 mm, 100/Pk - SF18182
Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. A syringe filter dispenses filtrate directly into an autosampler vial, without the intermediate collection vessel a bulk vacuum filtration setup typically needs. Hydrophobic PTFE repels water while passing gases and solvents freely while clarifying solvent streams at the rated pore size and stays chemically inert against solvents, acids, and alkalis. Polypropylene construction maintains a low-dead-volume internal flow path while shedding virtually no extractable material into the sample and presses snugly against the membrane during the pass. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.
Membrane Characteristics
- Hydrofluoric acid resistance holds even in fully acid-digested samples
- Stable across a wide operating temperature range for demanding methods
- Solvent tolerance includes full-strength tetrahydrofuran and chlorinated solvents such as dichloromethane
- Surface energy near 18.5 dynes per centimeter repels oils and nonpolar liquids
- Ionic and metallic extractable levels stay very low
Housing Characteristics
- Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
- Plasticizer-free polyolefin construction keeps the fluid path clean
- Impact-tolerant polypropylene body withstands routine bench handling without damage
- Translucent housing wall allows visual confirmation of sample flow during filtration
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Reliable solvent prefiltration keeps a stray particulate from carrying into your downstream work before it carries into further processing. Request comparable filtration options that may offer cost savings for your order from the Tisch Scientific team.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 4.35(absolute ethyl alcohol )
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 13mm
- Filtration Area
- 1.09cm²
- Flow Rate
- 20ml
- Holdup Volume
- 10μL
- Incompatibility
- Aqueous samples without rewetting
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 1.0
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 10ml
- Weight
- 0.19
- Wettability
- Hydrophobic
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
- Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
- Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
- Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.