Tisch Scientific PTFE Syringe Filters, 3 µm, 13 mm, 100/Pk - SF18183
Tisch Scientific holds its filtration pricing at levels that let budget-conscious laboratories stretch procurement dollars further. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. The PTFE membrane clarifies solvent streams at the rated pore size while resisting attack from the harshest process chemistries and suits solvent filtration where other membranes fail. Polypropylene construction maintains a low-dead-volume internal flow path and holds its seal true run after run. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.
Membrane Characteristics
- Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
- Absolute pore rating delivers reproducible retention across every protocol
- Solvent tolerance includes full-strength tetrahydrofuran and chlorinated solvents such as dichloromethane
- UL 94 V-0 rating confirms the highest self-extinguishing classification
- Non-fibrous, fully synthetic structure sheds no fibers into filtrate
Housing Characteristics
- Stable across the full aqueous pH range in routine sample work
- Optimized internal geometry minimizes backpressure in service
- Polypropylene housing withstands rated backpressure from dense sample matrices without deformation
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Start a live chat with the Tisch Scientific team for real-time updates on product availability, lead time, or your order status.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 2.9(absolute ethyl alcohol )
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 13mm
- Filtration Area
- 1.09cm²
- Flow Rate
- 60ml
- Holdup Volume
- 10μL
- Incompatibility
- Aqueous samples without rewetting
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-140μm
- Pack Count
- 100
- Pore Size (µm)
- 3.0
- Sterility
- NonSterile
- Sterilization
- Autoclave 121°C for 30min/ Gamma 25kGy
- Volume Throughput (ml)
- 10ml
- Weight
- 0.19
- Wettability
- Hydrophobic
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
- Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
- Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.