Chat with us, powered by LiveChat

Secure Checkout
PTFE Syringe Filters, 1.0um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

Thumbnail Filmstrip of PTFE Syringe Filters, 1.0um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk Images

    Purchase PTFE Syringe Filters, 1.0um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

    PTFE Syringe Filters, 1.0um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk
    Tisch SKU: SF18275

    $152.95
    Ships in 4 weeks
     

    Tisch Scientific PTFE Syringe Filters, 1 µm, 13 mm, 100/Pk - SF18275

    Tisch Scientific makes the ordering process straightforward, turning around requests for pricing and product information fast. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. PTFE filters aggressive organic solvents without swelling or breakdown while repelling water and passing gases and solvents freely and resists attack from the harshest process chemistries. The polypropylene housing routes flow to minimize backpressure in service while preserving sample chemistry across the flow path and is supplied pre-sterilized in individual packaging for sterile sample preparation. For routine sample preparation across many methods, each analytical run starts with a consistent, particle-free sample without added hardware or a cleaning step.

    Membrane Characteristics

    • Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
    • Ionic and metallic extractable levels stay very low
    • Chemical resistance spans the full pH 1 to 14 range
    • Minimal moisture absorption pairs with a low tare mass
    • Hydrofluoric acid resistance holds even in fully acid-digested samples

    Housing Characteristics

    • Thermal-bonded construction keeps adhesives out of the fluid path
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
    • PP housing supplied sterile in individual packaging for immediate use in aseptic filtration without bench preparation

    An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Request comparable filtration options that may offer cost savings for your order from the Tisch Scientific team.

    Sterilization Guidance

    Factory sterilization supports immediate use in workflows where sterility assurance matters.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    4.35(absolute ethyl alcohol )
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    13mm
    Filtration Area
    1.09cm²
    Flow Rate
    20ml
    Holdup Volume
    10μL
    Incompatibility
    Aqueous samples without rewetting
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-140μm
    Pack Count
    100
    Pore Size (µm)
    1.0
    Sterility
    Sterile
    Volume Throughput (ml)
    10ml
    Weight
    0.40
    Wettability
    Hydrophobic
    • Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
    • Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
    • Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
    • Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
    • Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.