Chat with us, powered by LiveChat

Secure Checkout
PVDF Syringe Filters, Hydrophilic,0.1um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of PVDF Syringe Filters, Hydrophilic,0.1um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase PVDF Syringe Filters, Hydrophilic,0.1um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    PVDF Syringe Filters, Hydrophilic,0.1um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF18074

    $172.95
    Ships in 4 weeks
     

    Tisch Scientific PVDF Syringe Filters, 0.1 µm, 25 mm, 100/Pk - SF18074

    Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. Sterilizing-grade syringe filters deliver sterile-grade retention as a single-use format, eliminating the autoclaving and cleaning cycle a reusable sterile filtration setup would require. A hydrophilic graft lets PVDF wet HPLC samples despite its fluoropolymer backbone and holds up to alcohols and mild hydrocarbon solvents. The PP housing sustains efficient flow on viscous samples while shedding virtually no extractable material into the sample and holds its seal true run after run. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.

    Membrane Characteristics

    • Adsorptive loss of HPLC analytes stays immeasurably low
    • Chemical compatibility spans the full pH 1 to 14 range
    • Hydrochloric, dilute nitric, and up to 90% sulfuric acid cause no attack
    • Resistance to hydrolytic degradation exceeds that of nylon membranes
    • Limiting oxygen index runs high, supporting flame resistance and low smoke

    Housing Characteristics

    • Polypropylene housing withstands rated backpressure from dense sample matrices without deformation
    • Resists stress cracking from aqueous salt and buffer solutions
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate

    An unfiltered buffer can foul your instrument and interrupt a run mid-sequence. Reliable particulate removal protects your instruments and your data across reagent, buffer, and mobile-phase preparation. Request blanket-order pricing and paperwork support for your routine filtration purchases.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    26.1psi
    Connection Type
    Luer-Lok/Luer Slip
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    8ml
    Holdup Volume
    100μL
    Material
    Polyvinylidene Fluoride (PVDF)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-130μm
    Pack Count
    100
    Pore Size (µm)
    0.1
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave at 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    50ml
    Weight
    0.52
    Wettability
    Hydrophilic
    • Protein Purification - Facilitates routine clarification of chromatography samples, preventing column fouling without binding target proteins.
    • Spectroscopy Prep - Provides optical clarity and low background interference, ideal for UV-Vis and fluorescence sample preparation work.
    • Beverage QC - Clarifies wine, beer, and juice samples ahead of HPLC testing for organic acids, sugars, and preservatives.
    • Pharmaceutical QC - Supports routine quality control testing by reliably filtering mild organic solvent mixtures and drug formulations daily.
    • Immunochemistry Research - Delivers exceptional chemical resistance for mild organic mixtures used in sensitive immunochemical research applications.
    • Trace Analysis - Prevents non-specific binding in trace analysis, keeping low-concentration analytes in solution for reliable detection.